DICOM PS3.16 2020a - Content Mapping Resource​ Page 771​

CID 6036 Scope of Feature​

Resources:​

HTML | FHIR JSON | FHIR XML | IHE SVS XML​

Type:​

Non-Extensible​

Version:​

20020904​

UID:​

1.2.840.10008.6.1.366​

Table CID 6036. Scope of Feature​

Coding Scheme Designator​

Code Value​

Code Meaning​

DCM​

111156​

Feature detected on the only image​

DCM​

111157​

Feature detected on only one of the images​

DCM​

111158​

Feature detected on multiple images​

DCM​

111159​

Feature detected on images from multiple modalities​

CID 6037 Mammography Quantitative Temporal Difference Type​

Resources:​

HTML | FHIR JSON | FHIR XML | IHE SVS XML​

Type:​

Extensible​

Version:​

20020904​

UID:​

1.2.840.10008.6.1.367​

Table CID 6037. Mammography Quantitative Temporal Difference Type​

Coding Scheme​

Code Value​

Code Meaning​

SNOMED-RT ID​ UMLS Concept Unique​

Designator​

 

 

ID​

SCT​

129806009​

Difference in size​

SCT​

129807000​

Difference in opacity​

SCT​

129808005​

Difference in location​

SCT​

129809002​

Difference in spatial proximity​

SCT​

129810007​

Difference in number of​

 

 

calcifications​

F-017B1​

C1268722​

F-017B2​

C1268723​

F-017B3​

C1268724​

F-017B4​

C1268725​

F-017B5​

C1268726​

CID 6038 Mammography Qualitative Temporal Difference Type​

Resources:​

HTML | FHIR JSON | FHIR XML | IHE SVS XML​

Type:​

Extensible​

Version:​

20020904​

UID:​

1.2.840.10008.6.1.368​

Table CID 6038. Mammography Qualitative Temporal Difference Type​

Coding Scheme​

Code Value​

Code Meaning​

SNOMED-RT ID​

UMLSConceptUniqueID​

Designator​

 

 

 

 

SCT​

129811006​

Difference in shape​

F-017B6​

C1268727​

SCT​

129812004​

Difference in margin​

F-017B7​

C1268728​

SCT​

129813009​

Difference in symmetry​

F-017B8​

C1268729​

CID 6039 Nipple Characteristic​

Resources:​

HTML | FHIR JSON | FHIR XML | IHE SVS XML​

Type:​

Extensible​

Version:​

20020904​

UID:​

1.2.840.10008.6.1.369​

- Standard -​


Page 772​ DICOM PS3.16 2020a - Content Mapping Resource​

Table CID 6039. Nipple Characteristic​

Coding Scheme​

Code Value​

Code Meaning​

SNOMED-RT ID​

UMLS Concept Unique ID​

Designator​

 

 

 

 

SCT​

31842008​

Normal shape​

M-02000​

C0332480​

SCT​

31845005​

Nipple retraction​

D7-90554​

C0221370​

CID 6040 Non-lesion Object Type​

Resources:​

HTML | FHIR JSON | FHIR XML | IHE SVS XML​

Type:​

Extensible​

Version:​

20170914​

UID:​

1.2.840.10008.6.1.370​

Table CID 6040. Non-lesion Object Type​

Coding Scheme​

Code Value​

Code Meaning​

SNOMED-RT ID​ UMLS Concept Unique​

Designator​

 

 

ID​

Include CID 6401

“Non-lesion Object Type - Physical Objects”​

 

Include CID 6402

“Non-lesion Object Type - Substances”​

 

Include CID 6403

“Non-lesion Object Type - Tissues”​

 

 

DCM​

 

111176​

Unspecified​

 

Note​

The use of (111176, DCM, "Unspecified") is explicitly permitted in this context group to allow for the communication of​ measurements of an object of unknown type using TID 4012 “Mammography CAD Non-lesion”.​

CID 6041 Mammography Image Quality Finding​

Resources:​

HTML | FHIR JSON | FHIR XML | IHE SVS XML​

Type:​

Extensible​

Version:​

20020904​

UID:​

1.2.840.10008.6.1.371​

Table CID 6041. Mammography Image Quality Finding​

Coding Scheme​

Code Value​

Code Meaning​

Source​

Designator​

 

 

 

DCM​

111177​

View and Laterality Marker is missing​

MQSA​

DCM​

111178​

View and Laterality Marker does not have both view​

MQCM 1999​

 

 

and laterality​

 

DCM​

111179​

View and Laterality Marker does not have approved​

MQCM 1999​

 

 

codes​

 

DCM​

111180​

View and Laterality Marker is not near the axilla​

MQCM 1999​

DCM​

111181​

View and Laterality Marker overlaps breast tissue​

MQCM 1999​

DCM​

111182​

View and Laterality Marker is partially obscured​

MQCM 1999​

DCM​

111183​

View and Laterality Marker is incorrect​

 

DCM​

111184​

View and Laterality Marker is off image​

 

DCM​

111185​

Flash is not near edge of film​

MQCM 1999​

DCM​

111186​

Flash is illegible, does not fit, or is lopsided​

MQSA​

DCM​

111187​

Flash doesn't include patient name and additional​

MQCM 1999​

 

 

patient id​

 

- Standard -​


 

DICOM PS3.16 2020a - Content Mapping Resource​

Page 773​

Coding Scheme​

Code Value​

Code Meaning​

Source​

Designator​

 

 

 

DCM​

111188​

Flash doesn't include date of examination​

MQCM 1999​

DCM​

111189​

Flash doesn't include facility name and location​

MQSA​

DCM​

111190​

Flash doesn't include technologist identification​

MQCM 1999​

DCM​

111191​

Flash doesn't include cassette/screen/detector​

MQCM 1999​

 

 

identification​

 

DCM​

111192​

Flashdoesn'tincludemammographyunitidentification​

MQCM 1999​

DCM​

111193​

Date sticker is missing​

MQCM 1999​

DCM​

111194​

Technical factors missing​

MQCM 1999​

DCM​

111195​

Collimation too close to breast​

MQCM 1999​

DCM​

111196​

Inadequate compression​

MQCM 1999​

DCM​

111197​

MLO Insufficient pectoral muscle​

MQCM 1999​

DCM​

111198​

MLO No fat is visualized posterior to fibroglandular​

MQCM 1999​

 

 

tissues​

 

DCM​

111199​

MLO Poor separation of deep and superficial breast​

MQCM 1999​

 

 

tissues​

 

DCM​

111200​

MLO Evidence of motion blur​

MQCM 1999​

DCM​

111201​

MLO Inframammary fold is not open​

MQCM 1999​

DCM​

111202​

CC Not all medial tissue visualized​

MQCM 1999​

DCM​

111203​

CC Nipple not centered on image​

MQCM 1999​

DCM​

111204​

CC Posterior nipple line does not measure within 1​

MQCM 1999​

 

 

cm of MLO​

 

DCM​

111205​

Nipple not in profile​

 

DCM​

111206​

Insufficient implant displacement incorrect​

MQCM 1999​

DCM​

111208​

Grid artifact(s)​

 

DCM​

111209​

Positioning​

 

DCM​

111210​

Motion blur​

 

DCM​

111211​

Under exposed​

 

DCM​

111212​

Over exposed​

 

DCM​

111213​

No image​

 

DCM​

111214​

Detector artifact(s)​

 

DCM​

111215​

Artifact(s) other than grid or detector artifact​

 

DCM​

111216​

Mechanical failure​

 

DCM​

111217​

Electrical failure​

 

DCM​

111218​

Software failure​

 

DCM​

111219​

Inappropriate image processing​

 

DCM​

111220​

Other failure​

 

DCM​

111221​

Unknown failure​

 

CID 6042 Status of Results​

 

 

Resources:​

HTML | FHIR JSON | FHIR XML | IHE SVS XML​

 

Type:​

Non-Extensible​

 

Version:​

20020904​

 

 

UID:​

1.2.840.10008.6.1.372​

 

- Standard -​


Page 774​ DICOM PS3.16 2020a - Content Mapping Resource​

Table CID 6042. Status of Results​

Coding Scheme Designator​

Code Value​

Code Meaning​

DCM​

111222​

Succeeded​

DCM​

111223​

Partially Succeeded​

DCM​

111224​

Failed​

DCM​

111225​

Not Attempted​

CID 6043 Types of Mammography CAD Analysis​

Resources:​

HTML | FHIR JSON | FHIR XML | IHE SVS XML​

Type:​

Extensible​

Version:​

20020904​

UID:​

1.2.840.10008.6.1.373​

Table CID 6043. Types of Mammography CAD Analysis​

Coding Scheme​

Code Value​

Code Meaning​

SNOMED-RT ID​

UMLS Concept​

Notes​

Designator​

 

 

 

Unique ID​

 

SCT​

133884007​

Spatial collocation analysis​

P5-B3402​

C1297892​

See Note 1​

SCT​

133885008​

Spatial proximity analysis​

P5-B3404​

C1297893​

See Note 2​

SCT​

133886009​

Temporal correlation​

P5-B3406​

C1297894​

 

SCT​

133887000​

Image quality analysis​

P5-B3408​

C1297895​

 

SCT​

133888005​

Focal asymmetric density analysis​

P5-B3410​

C1297896​

 

SCT​

133889002​

Asymmetric breast tissue analysis​

P5-B3412​

C1297897​

 

SCT​

133890006​

Breast composition analysis​

P5-B3414​

C1297898​

 

DCM​

111233​

Individual Impression /​

 

 

 

 

 

Recommendation Analysis​

 

 

 

DCM​

111234​

Overall Impression /​

 

 

 

 

 

Recommendation Analysis​

 

 

 

Note​

1.​Spatial Collocation Analysis is used to identify features that are the same or located in the same place.​

2.​Spatial Proximity Analysis is used to identify features that are related spatially, such as nipple retraction associated with​ a spiculated mass.​

CID 6044 Types of Image Quality Assessment​

Resources:​

HTML | FHIR JSON | FHIR XML | IHE SVS XML​

Type:​

Extensible​

Version:​

20020904​

UID:​

1.2.840.10008.6.1.374​

Table CID 6044. Types of Image Quality Assessment​

Coding Scheme Designator​

Code Value​

Code Meaning​

DCM​

111235​

Unusable - Quality renders image unusable​

DCM​

111236​

Usable - Does not meet the quality control standard​

DCM​

111237​

Usable - Meets the quality control standard​

- Standard -​