DICOM PS3.16 2020a - Content Mapping Resource Page 775
CID 6045 Mammography Types of Quality Control Standard
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Extensible |
Version: |
20020904 |
UID: |
1.2.840.10008.6.1.375 |
Table CID 6045. Mammography Types of Quality Control Standard
Coding Scheme Designator |
Code Value |
Code Meaning |
DCM |
111238 |
Mammography Quality Control Manual 1999, ACR |
DCM |
111239 |
Title 21 CFR Section 900, Subpart B |
DCM |
111240 |
Institutionally defined quality control standard |
CID 6046 Units of Follow-up Interval
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Extensible |
Version: |
20020904 |
UID: |
1.2.840.10008.6.1.376 |
Table CID 6046. Units of Follow-up Interval
Coding Scheme Designator |
Code Value |
Code Meaning |
UCUM |
d |
day |
UCUM |
wk |
week |
UCUM |
mo |
month |
UCUM |
a |
year |
CID 6047 CAD Processing and Findings Summary
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Non-Extensible |
Version: |
20020904 |
UID: |
1.2.840.10008.6.1.377 |
Table CID 6047. CAD Processing and Findings Summary
Coding Scheme Designator |
Code Value |
Code Meaning |
DCM |
111241 |
All algorithms succeeded; without findings |
DCM |
111242 |
All algorithms succeeded; with findings |
DCM |
111243 |
Not all algorithms succeeded; without findings |
DCM |
111244 |
Not all algorithms succeeded; with findings |
DCM |
111245 |
No algorithms succeeded; without findings |
CID 6048 CAD Operating Point Axis Label
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Extensible |
Version: |
20060612 |
UID: |
1.2.840.10008.6.1.378 |
Page 776 DICOM PS3.16 2020a - Content Mapping Resource
Table CID 6048. CAD Operating Point Axis Label
Coding Scheme Designator |
Code Value |
Code Meaning |
DCM |
111012 |
Certainty of Finding |
DCM |
111047 |
Probability of cancer |
DCM |
111086 |
False Markers per Image |
DCM |
111087 |
False Markers per Case |
DCM |
111088 |
Case Sensitivity |
DCM |
111089 |
Lesion Sensitivity |
DCM |
111090 |
Case Specificity |
DCM |
111091 |
Image Specificity |
CID 6050 Breast Procedure Reported
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Extensible |
Version: |
20190912 |
UID: |
1.2.840.10008.6.1.379 |
Table CID 6050. Breast Procedure Reported
Coding Scheme |
Code Value |
Code Meaning |
SNOMED-RT IDUMLS Concept Unique |
Designator |
|
|
|
|
ID |
DCM |
111408 |
Film Screen Mammography |
|
|
|
SCT |
47079000 |
Ultrasonography of breast |
|
P5-B8500 |
C0080264 |
SCT |
241615005 |
MRI of breast |
|
P5-0900D |
C0344104 |
SCT |
237380007 |
Pre-biopsy localization of breast lesion |
|
P1-48011 |
C0473515 |
SCT |
387736007 |
Fine needle aspiration of breast |
|
P1-48145 |
C0542415 |
SCT |
287572003 |
Diagnostic aspiration of breast cyst |
|
P1-48142 |
C0565162 |
SCT |
44578009 |
Core needle biopsy of breast |
|
P1-48304 |
C0191853 |
SCT |
274331003 |
Breast - surgical biopsy |
|
P1-4830F |
C0585992 |
SCT |
18102001 |
Mammary ductogram |
|
P5-40060 |
C0203033 |
SCT |
241539009 |
CT of breast |
|
P5-0801C |
C0412609 |
SCT |
66377006 |
Radionuclidelocalizationoftumor,limited |
P5-D0042 |
C0203652 |
|
|
area |
|
|
|
SCT |
80865008 |
Specimen radiography of breast |
|
P5-40030 |
C0203031 |
SCT |
46662001 |
Examination of breast |
|
P2-4A000 |
C0199850 |
DCM |
111410 |
Surgical consult |
|
|
|
DCM |
111411 |
Mammography CAD |
|
|
|
SCT |
396487001 |
Sentinel lymph node biopsy |
|
P1-65359 |
C0796693 |
SCT |
169167001 |
Radioisotope scan of lymphatic system |
|
P5-D0061 |
C0412375 |
DCM |
111123 |
Marker placement |
|
|
|
SCT |
45211000 |
Insertion of catheter |
|
P1-05535 |
C0007430 |
LN |
36626-0 |
breast - bilateral mammogram |
|
|
C1524974 |
LN |
30795-9 |
breast - bilateral mr |
|
|
C1114600 |
LN |
36150-1 |
breast - bilateral mr w contrast iv |
|
|
C1524494 |
LN |
36277-2 |
breast - bilateral mr wo and w contrast iv |
|
C1524125 |
|
DICOM PS3.16 2020a - Content Mapping Resource |
Page 777 |
Coding Scheme |
Code Value |
Code Meaning |
SNOMED-RT IDUMLS Concept Unique |
Designator |
|
|
|
ID |
LN |
46342-2 |
breast ffd mammogram |
|
C1830243 |
LN |
36627-8 |
breast - left mammogram |
|
C1524975 |
LN |
35954-7 |
breast - left mr |
|
C1524349 |
LN |
36151-9 |
breast - left mr w contrast iv |
|
C1524495 |
LN |
36278-0 |
breast - left mr wo and w contrast iv |
|
C1524126 |
LN |
36149-3 |
breast mr w contrast iv |
|
C1524493 |
LN |
36276-4 |
breast mr wo and w contrast iv |
|
C1524610 |
LN |
37774-7 |
breast - right mammogram |
|
C1525124 |
LN |
35955-4 |
breast - right mr |
|
C1524350 |
LN |
36152-7 |
breast - right mr w contrast iv |
|
C1524496 |
LN |
36279-8 |
breast - right mr wo and w contrast iv |
|
C1524127 |
LN |
36279-8 |
breast - right mr wo and w contrast iv |
|
C1524127 |
LN |
46339-8 |
breast - unilateral mammogram |
|
C1830240 |
LN |
46299-4 |
breast - unilateral mr |
|
C1830200 |
LN |
46323-2 |
breast - unilateral mr w contrast iv |
|
C1830224 |
LN |
43528-9 |
breast - unilateral mr wo and w contrast |
C1714927 |
|
|
iv |
|
|
LN |
46333-1 |
breast - unilateral mr wo contrast |
|
C1830234 |
LN |
46305-9 |
whole body ct |
|
C1830206 |
LN |
44139-4 |
whole body pt w rnc iv |
|
C1715409 |
Note
1.(241615005, SCT, "MRI of breast") is used historically in preference to (30794-2, LN, "breast mr") even though LOINC is used for more specific pre-coordinated concepts.
2.(46342-2, LN, "breast ffd mammogram") is used in place of the retired (111409, DCM, "Digital Mammography").
CID 6051 Breast Procedure Reason
Note |
|
Some of these terms were obtained from BI-RADS® |
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Extensible |
Version: |
20160314 |
UID: |
1.2.840.10008.6.1.380 |
Table CID 6051. Breast Procedure Reason
Coding Scheme |
Code Value |
Code Meaning |
SNOMED-RTIDUMLS Concept |
Designator |
|
|
Unique ID |
Include CID 6061 “Breast Imaging Procedure Modifiers” |
|
DCM |
111415 |
Additional evaluation requested from prior |
|
|
|
study |
|
DCM |
111416 |
Follow-up at short interval from prior study |
|
DCM |
111417 |
Historyofbreastaugmentation,asymptomatic |