DICOM PS3.16 2020a - Content Mapping Resource​

Page 1195​

Code Value​

Code Meaning​

Definition​

Notes​

111637​ AccumulatedAverageGlandular​Average Glandular Dose to a single breast accumulated​

 

 

Dose​

over multiple images.​

 

111638​

Patient Equivalent Thickness​

Value of the control variable used to parametrize the​

 

 

 

Automatic Exposure Control (AEC) closed loop. E.g.,​

 

 

 

"Water Value".​

 

111641​

Fixed grid​

An X-Ray Grid that does not move during exposure.​

 

111642​

Focused grid​

An X-Ray Grid with radiation absorbing strips that are​

 

 

 

focused toward the focal spot, to eliminate grid cutoff.​

 

111643​

Reciprocating grid​

AnX-RayGridthatisdesignedtomoveduringexposure,​

 

 

 

to eliminate the appearance of grid lines on the image.​

 

111644​

Parallel grid​

An X-Ray Grid with radiation absorbing strips that are​

 

 

 

parallel to each other and that is used only with long​

 

 

 

source to image distances.​

 

111645​

Crossed grid​

An X-Ray Grid with crossed radiation absorbing strips​

 

 

 

used for more complete cleanup of scatter radiation.​

 

111646​

No grid​

No X-Ray Grid was used due to low scatter conditions.​

 

111647​

Compression Force​

The compression force applied to the body part during​

 

 

 

exposure.​

 

111648​

Compression Pressure​

The average compression pressure applied to the body​

 

 

 

part during exposure.​

 

111649​

Compression Contact Area​

Theareaofthebodyparttowhichcompressionhasbeen​

 

 

 

applied during exposure.​

 

111671​ Spectacle Prescription Report​The spectacle prescription for a patient.​

 

111672​

Add Near​

Refractivemeasurementsoftheeyetocorrectforinability​

 

 

 

to focus at near while wearing the distance prescription.​

 

111673​

Add Intermediate​

Refractivemeasurementsoftheeyetocorrectforinability​

 

 

 

to focus at intermediate distance while wearing the​

 

 

 

distance prescription.​

 

111674​

Add Other​

Refractivemeasurementsoftheeyetocorrectforinability​

 

 

 

to focus at the specified distance while wearing the​

 

 

 

distance prescription.​

 

111675​

Horizontal Prism Power​

The power of a prism to bend light in the horizontal​

 

 

 

direction, in prism diopters.​

 

111676​

Horizontal Prism Base​

Direction of the base of a horizontal prism -- either in​

 

 

 

(toward the nose), or out (away from the nose).​

 

111677​

Vertical Prism Power​

Thepowerofaprismtobendlightintheverticaldirection,​

 

 

 

in prism diopters.​

 

111678​

Vertical Prism Base​

Direction of the base of a vertical prism -- either up, or​

 

 

 

down.​

 

111679​

Distance Pupillary Distance​

Distance in mm between the pupils when the patient's​

 

 

 

object of regard is in the distance.​

 

111680​

Near Pupillary Distance​

Distance in mm between the pupils when the patient's​

 

 

 

object of regard is at near.​

 

111681​

SMILE​

Small Incision Lenticule Extraction. Refractive surgery​

 

 

 

procedure where a thin lenticule is cleaved from the​

 

 

 

corneal stroma using a femtosecond laser and then​

 

 

 

extracted through a small incision in the corneal​

 

 

 

periphery.​

 

- Standard -​


Page 1196​

DICOM PS3.16 2020a - Content Mapping Resource​

 

Code Value​

Code Meaning​

Definition​

Notes​

111685​

Autorefraction Visual Acuity​

A patient's vision with the correction measured by an​

 

 

 

autorefractor in place.​

 

111686​

Habitual Visual Acuity​

A patient's vision with whichever vision correction the​

 

 

 

patient customarily wears.​

 

111687​

Prescription Visual Acuity​

A patient's vision with the final spectacle prescription in​

 

 

 

place.​

 

111688​

Right Eye Rx​

The spectacle prescription for the right eye.​

 

111689​

Left Eye Rx​

The spectacle prescription for the left eye.​

 

111690​ Macular Grid Thickness and​

Amaculargridthicknessandvolumereportforapatient.​

 

 

Volume Report​

The macular grid is an analytic tool described in PS3.1.​

 

111691​ Number of Images Used for​

Number of images used for the macular grid​

 

 

Macular Measurements​

measurement.​

 

111692​ Number of Samples Used per​ Number of samples used per Image for analysis.​

 

 

Image​

 

 

111693​

Analysis Quality Rating​

A numeric rating of the quality of the entire analysis with​

 

 

 

respect to grading and diagnostic purposes.​

 

 

 

Higher numbers indicate greater quality.​

 

111694​ Image Set Quality Rating​

Anumericratingofthequalityofanentireimagesetwith​

 

 

 

respect to grading and diagnostic purposes.​

 

 

 

Higher numbers indicate greater quality.​

 

111695​ Interfering Tears or Drops​

Tear film or drops affecting test quality.​

 

111696​ Visual Fixation Quality During​ The assessment of the centricity and persistence of the​

 

 

Acquisition​

visual fixation (direction of gaze) during the acquisition.​

 

111697​ Visual Fixation Quality Problem​The reason why the patient's visual fixation was not​

 

 

 

steady or was indeterminate.​

 

111698​

Ophthalmic Macular Grid​

The reason why the macular grid measurements may​

 

 

Problem​

be questionable.​

 

111700​ Specimen Container Identifier​ Identifierofcontainer(box,block,microscopeslide,etc.)​

 

 

 

for the specimen under observation.​

 

111701​

Processing type​

Type of processing that tissue specimen underwent.​

 

111702​

DateTime of processing​

Date and time of processing step.​

 

111703​

Processing step description​

Descriptionoftheindividualstepinthetissueprocessing​

 

 

 

sequence.​

 

111704​

Sampling Method​

Method of sampling used to derive specimen from its​

 

 

 

parent.​

 

111705​

Parent Specimen Identifier​

Identifier of the parent specimen that gave rise to the​

 

 

 

current specimen.​

 

111706​ Issuer of Parent Specimen​

Assigning authority for parent specimen's identifier.​

 

 

Identifier​

 

 

111707​

Parent specimen type​

Parentspecimentypethatgaverisetocurrentspecimen.​

 

111708​ Position Frame of Reference​

Description of coordinate system and origin reference​

 

 

 

pointonparentspecimen,orparentspecimencontainer,​

 

 

 

or image used for localizing the sampling site or location​

 

 

 

within container or image.​

 

111709​ Location of sampling site​

Reference to image of parent specimen localizing the​

 

 

 

samplingsite;mayincludereferencedPresentationState​

 

 

 

object.​

 

- Standard -​


 

DICOM PS3.16 2020a - Content Mapping Resource​

Page 1197​

Code Value​

Code Meaning​

Definition​

Notes​

111710​ Location of sampling site X​

Location of sampling site of specimen (nominal center)​

 

 

offset​

relative to the Position Frame of Reference.​

 

111711​ Location of sampling site Y​

Location of sampling site of specimen (nominal center)​

 

 

offset​

relative to the Position Frame of Reference.​

 

111712​

LocationofsamplingsiteZoffset​Location of sampling site of specimen (nominal center)​

 

 

 

relative to the Position Frame of Reference.​

 

111718​

Location of Specimen​

Descriptionofspecimenlocation,eitherinabsoluteterms​

 

 

 

or relative to the Position Frame of Reference.​

 

111719​ Location of Specimen X offset​Location of specimen (nominal center) relative to the​ Position Frame of Reference in the X dimension.​

111720​ Location of Specimen Y offset​Location of specimen (nominal center) relative to the​ Position Frame of Reference in the Y dimension.​

111721​ Location of Specimen Z offset​Location of specimen (nominal center) relative to the​ Position Frame of Reference in the Z dimension.​

111723​

Visual Marking of Specimen​

Description of visual distinguishing identifiers. E.g., ink,​

 

 

or a particular shape of the specimen.​

111724​

Issuer of Specimen Identifier​

Assigning authority for specimen identifier.​

111726​ Dissection with entire specimen​Dissectionofspecimenwithsubmissionofallitssections​ submission​ for further processing or examination.​

111727​ Dissection with representative​Dissectionofspecimenwithsubmissionofrepresentative​

 

sections submission​

sections for further processing or examination.​

111729​

Specimen storage​

A workflow step, during which tissue specimens are​

 

 

stored in a climate-controlled environment.​

111741​

Transmission illumination​

Transmission illumination method for specimen​

 

 

microscopy.​

111742​

Reflection illumination​

Reflectionilluminationmethodforspecimenmicroscopy.​

111743​

Epifluorescence illumination​

Epifluorescence illumination method for specimen​

 

 

microscopy.​

111744​

Brightfield illumination​

Brightfieldilluminationmethodforspecimenmicroscopy.​

111745​

Darkfield illumination​

Darkfield illumination method for specimen microscopy.​

111746​

Oblique illumination​

Oblique illumination method for specimen microscopy.​

111747​

Phase contrast illumination​

Phase contrast illumination method for specimen​

 

 

microscopy.​

111748​

Differentialinterferencecontrast​Differential interference contrast method for specimen​

 

 

microscopy.​

111749​

Total internal reflection​

Total internal reflection fluorescence method for​

 

fluorescence​

specimen microscopy.​

111750​

Ultrasound Contact​

A method of obtaining ophthalmic axial measurements​

 

 

that uses ultrasound, and that requires applanation of​

 

 

the cornea.​

111751​

Ultrasound Immersion​

A method of obtaining ophthalmic axial measurements​

 

 

that uses ultrasound, and that requires immersion of the​

 

 

patient's eye in fluid as he lies in a supine position.​

111752​

Optical​

A method of obtaining ophthalmic axial measurements​

 

 

that uses light.​

111753​

Manual Keratometry​

Measurements taken of the corneal curvature using a​

 

 

manual keratometer.​

- Standard -​


Page 1198​

DICOM PS3.16 2020a - Content Mapping Resource​

 

Code Value​

Code Meaning​

Definition​

Notes​

111754​

Auto Keratometry​

Measurements taken of the corneal curvature using an​

 

 

 

automated keratometer.​

 

111755​

Simulated Keratometry​

Simulated Keratometry measurements derived from​

 

 

 

corneal topography.​

 

111756​

Equivalent K-reading​

Corneal power measurements using Scheimpflug​

 

 

 

camera.​

 

111757​

Keratometry Measurements​

Keratometry Measurements DICOM SOP Instance.​

 

 

SOP Instance​

 

 

111758​

Total Cornea Power​

Method of determining the total cornea power from​

 

 

Measurement Method​

measuring the curvature of both anterior and posterior​

 

 

 

surface of the cornea.​

 

111759​

Posterior Cornea Surface​

Method of measuring the curvature of posterior surface​

 

 

Measurement Method​

of the cornea and determining its refractive power.​

 

111760​

Haigis​

The Haigis IOL calculation formula.​

 

 

 

Haigis W, Lege B, Miller N, Schneider B. Comparison of​

 

 

 

immersion ultrasound biometry and partial coherence​

 

 

 

interferometry for intraocular lens calculation according​

 

 

 

to Haigis. Graefes Arch Clin Exp Ophthalmol​

 

 

 

2000;238:765-73.​

 

111761​

Haigis-L​

The Haigis-L IOL calculation formula.​

 

 

 

Haigis W. Intraocular lens calculation after refractive​

 

 

 

surgery for myopia: Haigis-L formula. J Cataract Refract​

 

 

 

Surg. 2008 Oct;34(10):1658-63.​

 

111762​

Holladay 1​

The Holladay 1 IOL calculation formula.​

 

 

 

Holladay JT, Prager TC, Chandler TY, Musgrove KH,​

 

 

 

Lewis JW, Ruiz RS. A three-part system for refining​

 

 

 

intraocular lens power calculations. J Cataract Refract​

 

 

 

Surg. 1988; 14:17-24.​

 

111763​

Holladay 2​

The Holladay 2 IOL calculation formula.​

 

111764​

Hoffer Q​

The Hoffer Q IOL calculation formula. Hoffer KJ. The​

 

 

 

Hoffer Q formula: a comparison of theoretic and​

 

 

 

regression formulas. J Cataract Refract Surg​

 

 

 

1993;19:700-12. Errata. J Cataract Refract Surg​

 

 

 

1994;20:677 and 2007;33:2-3.​

 

111765​

Olsen​

The Olsen IOL calculation formula. Olsen T. Calculation​

 

 

 

of intraocular lens power: a review. Acta Ophthalmol.​

 

 

 

Scand. 2007: 85: 472-485.​

 

111766​

SRKII​

TheSRKIIIOLcalculationformula.SandersDR,Retzlaff​

 

 

 

J,KraffMC.ComparisonoftheSRKIIformulaandother​

 

 

 

second generation formulas. J Cataract Refract Surg.​

 

 

 

1988 Mar;14(2):136-41.​

 

111767​

SRK-T​

The SRK-T IOL calculation formula.​

 

 

 

Retzlaff JA, Sanders DR, Kraff MC. Development of the​

 

 

 

SRK/Tintraocularlensimplantpowercalculationformula.​

 

 

 

J Cataract Refract Surg 1990;16:333-40. Erratum​

 

 

 

1990;16:528.​

 

111768​

ACD Constant​

The "ACD Constant" used in IOL calculation.​

 

111769​

Haigis a0​

The "Haigis a0" constant used in IOL calculation.​

 

- Standard -​


 

DICOM PS3.16 2020a - Content Mapping Resource​

Page 1199​

Code Value​

Code Meaning​

Definition​

Notes​

111770​

Haigis a1​

The "Haigis a1" constant used in IOL calculation.​

 

111771​

Haigis a2​

The "Haigis a2" constant used in IOL calculation.​

 

111772​

Hoffer pACD Constant​

The "Hoffer pACD Constant" used in IOL calculation.​

 

111773​

Surgeon Factor​

The "Surgeon Factor" constant used in IOL calculation.​

 

111776​ Front Of Cornea To Front Of​

Anteriorchamberdepthdefinedasthefrontofthecornea​

 

 

Lens​

to the front of the lens.​

 

111777​ Back Of Cornea To Front Of​

Anteriorchamberdepthdefinedasthebackofthecornea​

 

 

Lens​

to the front of the lens.​

 

111778​ Single or Anterior Lens​

Refers to the anterior lens when there are two lenses in​

 

 

 

the eye. The distance, in mm, from the anterior surface​

 

 

 

of the lens to the posterior surface of the lens.​

 

111779​

Posterior Lens​

Refers to the posterior lens when there are two lenses​

 

 

 

intheeye.Thedistance,inmm,fromtheanteriorsurface​

 

 

 

of the lens to the posterior surface of the lens.​

 

111780​ MeasurementFromThisDevice​Value obtained from measurements taken by the device​

 

 

 

creating this SOP Instance.​

 

111781​

External Data Source​

Value obtained by data transfer from an external source​

 

 

 

- not from measurements taken by the device providing​

 

 

 

the value.​

 

111782​

Axial Measurements SOP​

Axial Measurements DICOM SOP Instance.​

 

 

Instance​

 

 

111783​ Refractive Measurements SOP​Refractive Measurements DICOM SOP Instance.​

 

 

Instance​

 

 

111784​ Autorefraction Measurements​ Autorefraction Measurements DICOM SOP Instance.​

 

 

SOP Instance​

 

 

111786​

Standard Deviation of​

StandardDeviationisasimplemeasureofthevariability​

 

 

measurements used​

of data.​

 

111787​ Signal to Noise Ratio​

SignaltoNoiseRatioofthedatasamplestakentocreate​

 

 

 

a measurement.​

 

111791​

Spherical projection​

Projection from 2D image pixels to 3D Cartesian​

 

 

 

coordinates based on a spherical mathematical model.​

 

111792​

Surface contour mapping​

Mapping from 2D image pixels to 3D Cartesian​

 

 

 

coordinates based on measurements of the retinal​

 

 

 

surface. E.g., of the retina, derived via a measurement​

 

 

 

technology such as Optical Coherence Tomography,​

 

 

 

Ultrasound etc.​

 

111800​ Visual Field 24-2 Test Pattern​ Test pattern, nominally covering an area within 24° of​ fixation. Consists of 54 test points a minimum of 3° from​ each meridian and placed 6° apart.​

The "-2" distinguishes this from another 24° pattern (no​ longer supported).​

111801​ Visual Field 10-2 Test Pattern​ Test pattern, nominally covering an area within 10° of​ fixation. Consists of 68 test points a minimum of 1° from​ each meridian and placed 2° apart.​

The"-2"inthiscaseindicatesitspointlayouttobesimilar​ to the 30-2 and 24-2.​

- Standard -​