DICOM PS3.16 2020a - Content Mapping Resource |
|
Code Value |
Code Meaning |
Definition |
Notes |
111685 |
Autorefraction Visual Acuity |
A patient's vision with the correction measured by an |
|
|
|
autorefractor in place. |
|
111686 |
Habitual Visual Acuity |
A patient's vision with whichever vision correction the |
|
|
|
patient customarily wears. |
|
111687 |
Prescription Visual Acuity |
A patient's vision with the final spectacle prescription in |
|
|
|
place. |
|
111688 |
Right Eye Rx |
The spectacle prescription for the right eye. |
|
111689 |
Left Eye Rx |
The spectacle prescription for the left eye. |
|
111690 Macular Grid Thickness and |
Amaculargridthicknessandvolumereportforapatient. |
|
|
Volume Report |
The macular grid is an analytic tool described in PS3.1. |
|
111691 Number of Images Used for |
Number of images used for the macular grid |
|
|
Macular Measurements |
measurement. |
|
111692 Number of Samples Used per Number of samples used per Image for analysis. |
|
|
Image |
|
|
111693 |
Analysis Quality Rating |
A numeric rating of the quality of the entire analysis with |
|
|
|
respect to grading and diagnostic purposes. |
|
|
|
Higher numbers indicate greater quality. |
|
111694 Image Set Quality Rating |
Anumericratingofthequalityofanentireimagesetwith |
|
|
|
respect to grading and diagnostic purposes. |
|
|
|
Higher numbers indicate greater quality. |
|
111695 Interfering Tears or Drops |
Tear film or drops affecting test quality. |
|
111696 Visual Fixation Quality During The assessment of the centricity and persistence of the |
|
|
Acquisition |
visual fixation (direction of gaze) during the acquisition. |
|
111697 Visual Fixation Quality ProblemThe reason why the patient's visual fixation was not |
|
|
|
steady or was indeterminate. |
|
111698 |
Ophthalmic Macular Grid |
The reason why the macular grid measurements may |
|
|
Problem |
be questionable. |
|
111700 Specimen Container Identifier Identifierofcontainer(box,block,microscopeslide,etc.) |
|
|
|
for the specimen under observation. |
|
111701 |
Processing type |
Type of processing that tissue specimen underwent. |
|
111702 |
DateTime of processing |
Date and time of processing step. |
|
111703 |
Processing step description |
Descriptionoftheindividualstepinthetissueprocessing |
|
|
|
sequence. |
|
111704 |
Sampling Method |
Method of sampling used to derive specimen from its |
|
|
|
parent. |
|
111705 |
Parent Specimen Identifier |
Identifier of the parent specimen that gave rise to the |
|
|
|
current specimen. |
|
111706 Issuer of Parent Specimen |
Assigning authority for parent specimen's identifier. |
|
|
Identifier |
|
|
111707 |
Parent specimen type |
Parentspecimentypethatgaverisetocurrentspecimen. |
|
111708 Position Frame of Reference |
Description of coordinate system and origin reference |
|
|
|
pointonparentspecimen,orparentspecimencontainer, |
|
|
|
or image used for localizing the sampling site or location |
|
|
|
within container or image. |
|
111709 Location of sampling site |
Reference to image of parent specimen localizing the |
|
|
|
samplingsite;mayincludereferencedPresentationState |
|
|
|
object. |
|