|
DICOM PS3.16 2020a - Content Mapping Resource |
Page 839 |
Coding Scheme Designator |
Code Value |
Code Meaning |
|
DCM |
109105 |
Frame Extracting Equipment |
|
DCM |
109106 |
Enhanced Multi-frame Conversion Equipment |
|
DCM |
MEDIM |
Portable Media Importer Equipment |
|
DCM |
FILMD |
Film Digitizer |
|
DCM |
DOCD |
Document Digitizer Equipment |
|
DCM |
VIDD |
Video Tape Digitizer Equipment |
|
CID 7006 SR Document Purposes of Reference |
|
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
|
Type: |
Extensible |
|
|
Version: |
20061023 |
|
|
UID: |
1.2.840.10008.6.1.487 |
|
|
Table CID 7006. SR Document Purposes of Reference |
|
Coding Scheme Designator |
Code Value |
Code Meaning |
|
DCM |
121331 |
Equivalent CDA Document |
|
DCM |
121332 |
Complete Rendering for Presentation |
|
DCM |
121333 |
Partial Rendering for Presentation |
|
DCM |
121334 |
Extended Rendering for Presentation |
|
DCM |
121335 |
Source Document |
|
CID 7007 Signature Purpose
Context Group ID 7007 comprises the signature purposes codes of ASTM E 2084-00. The Coding Scheme Designator (0008,0102) shall be "ASTM-sigpurpose". The ASTM document defines the signature purpose codes as OIDs. For the purposes of this Coding Scheme only the leaf digit is used as the Code Value (0008,0100).
Note
ASTM E 1762 provides the full definitions for the signature purpose OIDs defined by E 2084. The recommended Code Meanings (0008,0104) are the titles of the definitions for the leaves of the OIDs. For example, the OID 1.2.840.10065.1.12.1 corresponds to the leaf "id-purpose-author", whose meaning could be encoded as "Author Signature" and whose code value is 1.
CID 7008 Media Import
This Context Group specifies items that may be conveyed in the Billing and Materials Management Module (see PS3.3).
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Extensible |
Version: |
20061024 |
UID: |
1.2.840.10008.6.1.489 |
Table CID 7008. Media Import
Coding Scheme Designator |
Code Value |
Code Meaning |
DCM |
110020 |
Sheet Film Digitized |
DCM |
110021 |
Cine Film Digitized |
DCM |
110022 |
Video Tape Digitized |
DCM |
110023 |
Paper Digitized |
Page 840 |
DICOM PS3.16 2020a - Content Mapping Resource |
Coding Scheme Designator |
Code Value |
Code Meaning |
DCM |
110024 |
CD Imported |
DCM |
110025 |
DVD Imported |
DCM |
110026 |
MOD Imported |
DCM |
110027 |
Studies Imported |
DCM |
110028 |
Instances Imported |
CID 7009 Purpose of Reference to Predecessor Report
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Extensible |
Version: |
20090826 |
UID: |
1.2.840.10008.6.1.818 |
Table CID 7009. Purpose of Reference to Predecessor Report
Coding Scheme Designator |
Code Value |
Code Meaning |
DCM |
121360 |
Replaced report |
DCM |
121361 |
Addended report |
DCM |
121362 |
Preliminary report |
DCM |
121363 |
Partial report |
DCM |
122073 |
Current procedure evidence |
Note
The concepts of replaced and addended correspond to REPLACEMENT and ADDENDUM in HL7 V2.6 Chapter 9, with the exception that an EDITED value is not supported due to incompatibility with HL7 CDA.
CID 7010 Key Object Selection Document Title
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Extensible |
Version: |
20190915 |
UID: |
1.2.840.10008.6.1.490 |
Table CID 7010. Key Object Selection Document Title
Coding Scheme Designator |
Code Value |
Code Meaning |
DCM |
113000 |
Of Interest |
DCM |
113001 |
Rejected for Quality Reasons |
DCM |
113002 |
For Referring Provider |
DCM |
113003 |
For Surgery |
DCM |
113004 |
For Teaching |
DCM |
113005 |
For Conference |
DCM |
113006 |
For Therapy |
DCM |
113007 |
For Patient |
DCM |
113008 |
For Peer Review |
DCM |
113009 |
For Research |
DCM |
113010 |
Quality Issue |
DCM |
113013 |
Best In Set |
Page 842 DICOM PS3.16 2020a - Content Mapping Resource
Table CID 7011. Rejected for Quality Reasons
Coding Scheme Designator |
Code Value |
Code Meaning |
DCM |
111207 |
Image artifact(s) |
DCM |
111208 |
Grid artifact(s) |
DCM |
111209 |
Positioning |
DCM |
111210 |
Motion blur |
DCM |
111211 |
Under exposed |
DCM |
111212 |
Over exposed |
DCM |
111213 |
No image |
DCM |
111214 |
Detector artifact(s) |
DCM |
111215 |
Artifact(s) other than grid or detector artifact |
DCM |
111216 |
Mechanical failure |
DCM |
111217 |
Electrical failure |
DCM |
111218 |
Software failure |
DCM |
111219 |
Inappropriate image processing |
DCM |
111220 |
Other failure |
DCM |
111221 |
Unknown failure |
DCM |
113026 |
Double exposure |
CID 7012 Best in Set
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Extensible |
Version: |
20020904 |
UID: |
1.2.840.10008.6.1.492 |
Table CID 7012. Best in Set
Coding Scheme Designator |
Code Value |
Code Meaning |
DCM |
113014 |
Study |
DCM |
113015 |
Series |
DCM |
113016 |
Performed Procedure Step |
DCM |
113017 |
Stage-View |
CID 7013 Non-Image Source Instance Purposes of Reference
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Extensible |
Version: |
20170914 |
UID: |
1.2.840.10008.6.1.1134 |
Table CID 7013. Non-Image Source Instance Purposes of Reference
Coding Scheme Designator |
Code Value |
Code Meaning |
DCM |
128224 |
Source measurement |
DCM |
128225 |
Source report |
DCM |
128226 |
Source raw data |
Include CID 7019 “Segmentation Non-Image Source Purposes of Reference”