Page 852 DICOM PS3.16 2020a - Content Mapping Resource
Table CID 7041. Calcium Scoring Patient Size Categories
CodingSchemeDesignator Code Value |
Code Meaning |
SNOMED-RT ID UMLS Concept Unique ID |
Include CID 7042 “CMDCTECC Calcium Scoring Patient Size Categories” |
|
CID 7042 CMDCTECC Calcium Scoring Patient Size Categories
Patient sizes for calibrating calcium scoring, from the Consortium for Multi-Detector CT Evaluation of Coronary Calcium.
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Non-Extensible |
Version: |
20100127 |
UID: |
1.2.840.10008.6.1.825 |
Table CID 7042. CMDCTECC Calcium Scoring Patient Size Categories
Coding Scheme Designator |
Code Value |
Code Meaning |
DCM |
113601 |
Small: < 32.0 cm lateral thickness |
DCM |
113602 |
Medium: 32.0-38.0 cm lateral thickness |
DCM |
113603 |
Large: > 38.0 cm lateral thickness |
CID 7050 De-identification Method
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Extensible |
Version: |
20170914 |
UID: |
1.2.840.10008.6.1.925 |
Table CID 7050. De-identification Method
Coding Scheme Designator |
Code Value |
Code Meaning |
DCM |
113100 |
Basic Application Confidentiality Profile |
DCM |
113101 |
Clean Pixel Data Option |
DCM |
113102 |
Clean Recognizable Visual Features Option |
DCM |
113103 |
Clean Graphics Option |
DCM |
113104 |
Clean Structured Content Option |
DCM |
113105 |
Clean Descriptors Option |
DCM |
113106 |
Retain Longitudinal Temporal Information Full Dates Option |
DCM |
113107 |
RetainLongitudinalTemporalInformationModifiedDatesOption |
DCM |
113108 |
Retain Patient Characteristics Option |
DCM |
113109 |
Retain Device Identity Option |
DCM |
113110 |
Retain UIDs Option |
DCM |
113111 |
Retain Safe Private Option |
DCM |
113112 |
Retain Institution Identity Option |
CID 7060 Encapsulated Document Source Purposes of Reference
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Extensible |
Version: |
20180403 |
UID: |
1.2.840.10008.6.1.1201 |
DICOM PS3.16 2020a - Content Mapping Resource Page 853
Table CID 7060. Encapsulated Document Source Purposes of Reference
Coding Scheme Designator |
Code Value |
Code Meaning |
DCM |
121324 |
Source image |
Include CID 7013 “Non-Image Source Instance Purposes of Reference”
CID 7061 Model Document Titles
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Extensible |
Version: |
20180403 |
UID: |
1.2.840.10008.6.1.1202 |
Table CID 7061. Model Document Titles
Coding Scheme |
Code Value |
Code Meaning |
SNOMED-RT |
UMLS Concept |
Designator |
|
|
ID |
Unique ID |
DCM |
121324 |
Source image |
|
|
LN |
85041-2 |
MR 3D CAM model |
|
C4297407 |
LN |
85040-4 |
CT 3D CAM model |
|
C4297408 |
DCM |
129018 |
US 3D CAM model |
|
|
DCM |
129019 |
Mixed Modality 3D CAM model |
|
|
DCM |
129020 |
PhotogrammetricImaging3DCAMmodel |
|
DCM |
129021 |
Laser Scanning 3D CAM model |
|
|
CID 7062 Purpose of Reference to Predecessor 3D Model
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Extensible |
Version: |
20180403 |
UID: |
1.2.840.10008.6.1.1203 |
This Context Group comprises reasons that a prior 3D model may be referenced by a newer instance.
Table CID 7062. Purpose of Reference to Predecessor 3D Model
Coding Scheme Designator |
Code Value |
Code Meaning |
DCM |
129010 |
Edited Model |
DCM |
129011 |
Component Model |
CID 7063 Model Scale Units
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Non-extensible |
Version: |
20180403 |
UID: |
1.2.840.10008.6.1.1204 |
This Context Group comprises all valid scale units that may be used in a 3D model.
Table CID 7063. Model Scale Units
Coding Scheme Designator |
Code Value |
Code Meaning |
UCUM |
m |
m |
UCUM |
cm |
cm |
Page 854 |
DICOM PS3.16 2020a - Content Mapping Resource |
Coding Scheme Designator |
Code Value |
Code Meaning |
UCUM |
|
mm |
mm |
UCUM |
|
um |
um |
CID 7064 Model Usage |
|
|
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
|
Type: |
Extensible |
|
|
Version: |
20180403 |
|
|
UID: |
1.2.840.10008.6.1.1205 |
|
|
This Context Group comprises intended uses for objects manufactured from a 3D model. The intended use can help to distinguish similar-appearing models.
Table CID 7064. Model Usage
Coding Scheme |
Code Value |
Code Meaning |
SNOMED-RT ID UMLS Concept |
Designator |
|
|
|
Unique ID |
DCM |
129012 |
Educational Intent |
|
|
SCT |
261004008 |
Diagnostic Intent |
R-408C3 |
C0348026 |
DCM |
129013 |
Planning Intent |
|
|
DCM |
129014 |
Tool Fabrication |
|
|
DCM |
129015 |
Prosthetic Fabrication |
|
|
DCM |
129016 |
Implant Fabrication |
|
|
DCM |
113680 |
Quality Control Intent |
|
|
DCM |
129017 |
Simulation Intent |
|
|
CID 7070 Real Time Video Rendition Titles
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Extensible |
Version: |
20190915 |
UID: |
1.2.840.10008.6.1.1303 |
Table CID 7070. Real Time Video Rendition Titles
Coding Scheme Designator |
Code Value |
Code Meaning |
Coding Scheme Designator |
Code Value |
Code Meaning |
DCM |
130370 |
RTV Rendition |
DCM |
130371 |
RTV Audio and Video Rendition |
DCM |
130372 |
RTV Stereo Video Rendition |
DCM |
130373 |
RTV Audio and Stereo Video Rendition |
CID 7100 RCS Registration Method Type
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Extensible |
Version: |
20040115 |
UID: |
1.2.840.10008.6.1.494 |