DICOM PS3.16 2020a - Content Mapping Resource​

Page 1275​

Code Value​

Code Meaning​

Definition​

Notes​

121202​ Area of Defined Region​

 

Retired. Replaced by​

 

 

 

(131184002, SCT, "Area of​

 

 

 

defined region").​

121206​

Distance​

A one dimensional, or linear, numeric measurement.​

 

121207​

Height​

Vertical measurement value.​

 

121208​

Inter-Marker Distance​

Distance between marks on a device of calibrated size.​

 

 

E.g., a ruler.​

 

121210​

Path​

 

Retired. Replaced by​

 

 

 

(121055, DCM, "Path").​

121211​

Path length​

Aonedimensional,orlinear,numericmeasurementalong​

 

 

a polyline.​

 

121213​

Perimeter Outline​

 

Retired. Replaced by​

 

 

 

(121057, DCM, "Perimeter​

 

 

 

Outline").​

121214​

Referenced Segmentation​

Frame selected from a segmentation image, specifically​

 

Frame​

the pixels/voxels identified as belonging to the​

 

 

 

classificationofthesegmentencompassingtheidentified​

 

 

frame.​

 

121216​ Volume estimated from single​ A three-dimensional numeric measurement that is​ 2D region​ approximate, based on a two-dimensional region in a​

single image.​

121217​ Volume estimated from three or​A three-dimensional numeric measurement that is​ more non-coplanar 2D regions​approximate, based on three or more non-coplanar​

two-dimensional image regions.​

121218​ Volume estimated from two​

A three-dimensional numeric measurement that is​

 

non-coplanar 2D regions​

approximate,basedontwonon-coplanartwo-dimensional​

 

 

image regions.​

121219​ Volume of bounding three​

A three-dimensional numeric measurement of the​

 

dimensional region​

boundingregionofathree-dimensionalregionofinterest​

 

 

in an image set.​

121220​ Volumeofcircumscribedsphere​A three-dimensional numeric measurement of the​

 

 

boundingsphereofathree-dimensionalregionofinterest​

 

 

in an image set.​

121221​

Volume of ellipsoid​

Athree-dimensionalnumericmeasurementofanellipsoid​

 

 

shaped three-dimensional region of interest in an image​

 

 

set.​

121222​

Volume of sphere​

A three-dimensional numeric measurement of a sphere​

 

 

shaped three-dimensional region of interest in an image​

 

 

set.​

121230​

Path Vertex​

Coordinates of a point on a defined path.​

121231​

Volume Surface​

Surface of an identified or measured volume.​

121232​ Source series for segmentation​Series of image instances used as source data for a​ segmentation.​

121233​ Source image for segmentation​Imageinstancesusedassourcedataforasegmentation.​

121242​

Distance from nipple​

Indicatesthelocationoftheareaofinterestasmeasured​

 

 

from the nipple of the breast.​

121243​

Distance from skin​

Indicatesthelocationoftheareaofinterestasmeasured​

 

 

from the most direct skin point of the breast.​

- Standard -​


Page 1276​

DICOM PS3.16 2020a - Content Mapping Resource​

 

Code Value​

Code Meaning​

Definition​

Notes​

121244​ Distance from chest wall​

Indicatesthelocationoftheareaofinterestasmeasured​

 

 

 

from the chest wall.​

 

121290​ Patient exposure to ionizing​

Patient exposure to ionizing radiation (procedure).​

 

 

radiation​

 

 

121291​

Results communicated​

The act of communicating actionable findings to a​

 

 

 

responsible receiver.​

 

121301​

Simultaneous Doppler​

Reference is to a Doppler waveform acquired​

 

 

 

simultaneously with an image.​

 

121302​

Simultaneous Hemodynamic​

Reference is to a Hemodynamic waveform acquired​

 

 

 

simultaneously with an image.​

 

121303​

Simultaneous ECG​

ReferenceistoaECGwaveformacquiredsimultaneously​

 

 

 

with an image.​

 

121304​ Simultaneous Voice Narrative​ Reference is to a voice narrative recording acquired​

 

 

 

simultaneously with an image.​

 

121305​

Simultaneous Respiratory​

A waveform representing chest expansion and​

 

 

Waveform​

contraction due to respiratory activity, measured​

 

 

 

simultaneously with the acquisition of this Image.​

 

121306​

Simultaneous Arterial Pulse​

Arterial pulse waveform obtained simultaneously with​

 

 

Waveform​

acquisition of a referencing image.​

 

121307​

Simultaneous​

Phonocardiographic waveform obtained simultaneously​

 

Phonocardiographic Waveform​with acquisition of a referencing image.​

121310​ RT treatment plan for the​ position being verified​

ThereferencedinstanceisanRTtreatmentplanofsome​The referenced Instance​ type, which contains treatment positioning information,​typically will be an RT Plan,​

which has been verified using the information in the​

RT Ion Plan or RT Radiation​

referencing instance.​

Set.​

121311​

Localizer​

Image providing an anatomical reference on the patient​

 

 

under examination, for the purpose of defining the​

 

 

location of the ensuing imaging.​

121312​

Biopsy localizer​

Image providing an anatomical reference on the patient​

 

 

under examination, for the purpose of planning or​

 

 

documenting a biopsy.​

121313​

Other partial views​

Image providing a partial view of the target anatomy,​

 

 

when the target anatomy is too large for a single image.​

121314​

Other image of biplane pair​

Image providing a view of the target anatomy in a​

 

 

different imaging plane, typically from a near​

 

 

perpendicular angle.​

121315​ Otherimageofstereoscopicpair​Image providing a view of the target anatomy in a​

 

 

different imaging plane, typically with a small angular​

 

 

difference.​

121316​

Images related to standalone​ Image related to a non-image information object.​

 

object​

 

121317​

Spectroscopy​

Image where signals are identified and separated​

 

 

according to their frequencies. E.g., to identify individual​

 

 

chemicals, or individual nuclei in a chemical compound.​

121318​

Spectroscopy Data for Water​

MR spectroscopy data acquired to correct the phase of​

 

Phase Correction​

the diagnostic data for the phase signal of the Water.​

121320​

Uncompressed predecessor​

An image that has not already been lossy compressed​

 

 

that is used as the source for creation of a lossy​

 

 

compressed image.​

- Standard -​


 

DICOM PS3.16 2020a - Content Mapping Resource​

Page 1277​

Code Value​

Code Meaning​

Definition​

Notes​

121321​ Mask image for image​

Image used as the mask for an image processing​

 

 

processing operation​

operation, such as subtraction.​

 

121322​ Source image for image​

Image used as the source for an image processing​

 

 

processing operation​

operation.​

 

121323​ Source series for image​

Series used as the source for an image processing​

 

 

processing operation​

operation.​

 

121324​

Source Image​

Image used as the source for a derived or compressed​

 

 

 

image.​

 

121325​

Lossy compressed image​

Imageencodedwithalossycompressiontransfersyntax.​

 

121326​ Alternate SOP Class instance​ SOP Instance encoded with a different SOP Class but​

 

 

 

otherwise equivalent data.​

 

121327​

Full fidelity image​

Full fidelity image, uncompressed or lossless​

 

 

 

compressed.​

 

121328​

Alternate Photometric​

Imageencodedwithadifferentphotometricinterpretation.​

 

 

Interpretation image​

 

 

121329​ Source image for montage​

Image used as a source for a montage (stitched) image.​

 

121330​ Lossycompressedpredecessor​An image that has previously been lossy compressed​

 

 

 

that is used as the source for creation of another lossy​

 

 

 

compressed image.​

 

121331​

Equivalent CDA Document​

HL7 Document Architecture (CDA) Document that​

 

 

 

contains clinical content equivalent to the referencing​

 

 

 

Instance.​

 

121332​ Complete Rendering for​ Presentation​

121333​ Partial Rendering for​ Presentation​

121334​ Extended Rendering for​ Presentation​

121335​ Source Document​

121338​ Anatomic image​ 121339​ Functional image​

121340​ Spectral filtered image​

121341​ Device localizer​

121342​ Dose Image​

121346​ Acquisition frames​ corresponding to volume​

121347​ Volume corresponding to​ spatially-related acquisition​ frames​

Instance that contains a displayable complete rendering​ of the referencing Instance.​

Instance that contains a displayable partial rendering of​ the referencing Instance.​

Instance that contains a displayable complete rendering​ of the referencing Instance, plus additional content such​ as inline rendering of referenced images.​

Document whose content has been wholly or partially​ transformed to create the referencing document.​

Image showing structural anatomic features.​ Image showing physical or chemical activity.​

Image providing the same view of the target anatomy​ acquired using only a specific imaging wavelength,​ frequency or energy.​

Image providing an anatomical reference on the patient​ under examination, for the purpose of documenting the​ location of device such as a diagnostic or therapeutic​ catheter.​

Image providing a graphic view of the distribution of​ radiation dose.​

The referenced image is the source of spatially-related​ frames from which the referencing 3D volume data was​ derived.​

3D Volume containing the spatially-related frames in the​ referencing instance.​

- Standard -​


Page 1278​

DICOM PS3.16 2020a - Content Mapping Resource​

 

Code Value​

Code Meaning​

Definition​

Notes​

121348​

Temporal Predecessor​

Instance acquired prior to the referencing instance in a​

 

 

 

set of consecutively acquired instances.​

 

121349​

Temporal Successor​

Instanceacquiredsubsequenttothereferencinginstance​

 

 

 

in a set of consecutively acquired instances.​

 

121350​ Same acquisition at lower​

Image of the same target area at lower resolution​

 

 

resolution​

acquired in the same acquisition process.​

 

121351​ Same acquisition at higher​

Image of the same target area at higher resolution​

 

 

resolution​

acquired in the same acquisition process.​

 

121352​ Same acquisition at different​

Image of the same target area at different focal depth​

 

 

focal depth​

(Z-plane) acquired in the same acquisition process.​

 

121353​ Same acquisition at different​

Image of the same target area at different spectral band​

 

 

spectral band​

acquired in the same acquisition process.​

 

121354​

Imaged container label​

Image specifically targeting the container label.​

 

121358​

For Processing predecessor​

SourceimagefromwhichFORPRESENTATIONimages​

 

 

 

were created.​

 

121360​

Replaced report​

The reference is to a predecessor report that has been​

 

 

 

replaced by the current report.​

 

121361​

Addended report​

The reference is to a predecessor report to which the​

 

 

 

current report provides an addendum.​

 

121362​

Preliminary report​

A report that precedes the final report and may contain​

 

 

 

only limited information; it may be time sensitive, and it​

 

 

 

is not expected to contain all the reportable findings.​

 

121363​

Partial report​

A report that is not complete.​

 

121370​ Composed from prior doses​

The dose object created was calculated by summation​

 

 

 

of existing, previously calculated, RT Dose instances.​

 

121371​ Composedfrompriordosesand​The dose object created was calculated by summation​

 

 

current plan​

of existing, previously calculated, RT Dose instances​

 

 

 

anddosenewlycalculatedbytheapplication.Thenewly​

 

 

 

calculateddosemayormaynotexistasanindependent​

 

 

 

object.​

 

121372​ Source dose for composing​

RT Dose Instances used as source for calculated dose.​

 

 

current dose​

 

 

121373​ RT Pre-Treatment Dose Check​An assessment of the dose delivery parameters​

 

 

 

performed before treatment.​

 

121374​ RT Pre-Treatment Consistency​An assessment of consistency with a previously​

 

 

Check​

quality-assured treatment plan performed before​

 

 

 

treatment.​

 

121375​

Assessment By Comparison​

The basis of the assessment was a comparison object.​

 

121376​

Assessment By Rules​

The basis of the assessment was a set of rules on​

 

 

 

expected values, ranges and relationships.​

 

121380​

Active Ingredient Undiluted​

Concentration of the chemically or physically interesting​

 

 

Concentration​

(active)ingredientofadrugorcontrastagentasdelivered​

 

 

 

inproductformfromthemanufacturer,typicallyinmg/ml.​

 

121381​

Contrast/Bolus Ingredient​

X-Ray absorption of the active ingredient of a contrast​

 

 

Opaque​

agent ingredient is greater than the absorption of water​

 

 

 

(tissue).​

 

121382​

Quantity administered​

Number of units of substance administered to a patient.​

 

 

 

E.g., tablets.​

 

121383​

Mass administered​

Mass of substance administered to a patient.​

 

- Standard -​


 

DICOM PS3.16 2020a - Content Mapping Resource​

Page 1279​

Code Value​

Code Meaning​

Definition​

Notes​

121384​

RT Plan Label​

Human readable label of the radiotherapy plan.​

 

121385​

Current Fraction Number​

The index of the fraction of the radiotherapy plan to be​

 

 

 

delivered.​

 

121386​ Number of Fractions Planned​ The total number of prescribed radiotherapy fractions.​

 

121387​

NumberofFractionsCompleted​The number of fully completed radiotherapy fractions of​

 

 

 

theradiotherapyplantobedelivered.Partiallycompleted​

 

 

 

fractions are not included.​

 

121388​

Checked-In Status​

Whetherornotthepatienthasbeenchecked-in,i.e.,are​

 

 

 

physically present and are waiting to be called in to the​

 

 

 

treatment room.​

 

121389​

Referenced Beam Number​

The referenced beam number within the radiotherapy​

 

 

 

plan to be delivered.​

 

121401​

Derivation​

Methodofderivingorcalculatingameasuredvalue.E.g.,​

 

 

 

mean, or maximum of set.​

 

121402​

Normality​

Assessmentofameasurementrelativetoanormalrange​

 

 

 

of values; may be considered subtype of term​

 

 

 

(363713009, SCT, "has interpretation").​

 

121403​

Level of Significance​

Significance of a measurement.​

 

121404​

Selection Status​

Status of selection of a measurement for further​

 

 

 

processing or use.​

 

121405​

Population description​

Description of a population of measurements.​

 

121406​

Reference Authority​

Bibliographic or clinical reference for a Description of a​

 

 

 

population of measurements.​

 

121407​

Normal Range description​

Description of a normal range of values for a​

 

 

 

measurement concept.​

 

121408​

Normal Range Authority​

Bibliographic or clinical reference for a Description of a​

 

 

 

normal range of values.​

 

121410​

User chosen value​

Observationvalueselectedbyuserforfurtherprocessing​

 

 

 

or use, or as most representative.​

 

121411​ Most recent value chosen​

Observationvalueistherecentlyobtained,andhasbeen​

 

 

 

selected for further processing or use.​

 

121412​

Mean value chosen​

Observationvalueisthemeanofseveralmeasurements,​

 

 

 

and has been selected for further processing or use.​

 

121414​

Standarddeviationofpopulation​Standard deviation of a measurement in a reference​

 

 

 

population.​

 

121415​

Percentile Ranking of​

Percentile Ranking of an observation value with respect​

 

 

measurement​

a reference population.​

 

121416​

Z-Score of measurement​

Z-scoreofanobservationvaluewithrespectareference​

 

 

 

population, expressed as the dimensionless quantity​

 

 

 

(x-m) /s, where (x-m) is the deviation of the observation​

 

 

 

value (x) from the population mean (m), and s is the​

 

 

 

standard deviation of the population.​

 

121417​ 2 Sigma deviation of population​2 Sigma deviation of a measurement in a reference​

 

 

 

population.​

 

121420​

Equation​

Formula used to compute a derived measurement.​

 

121421​

Equation Citation​

Bibliographic reference to a formula used to compute a​

 

 

 

derived measurement; reference may be to a specific​

 

 

 

equation in a journal article.​

 

- Standard -​