ВУЗ: Не указан

Категория: Не указан

Дисциплина: Не указана

Добавлен: 10.04.2024

Просмотров: 756

Скачиваний: 0

ВНИМАНИЕ! Если данный файл нарушает Ваши авторские права, то обязательно сообщите нам.

 

DICOM PS3.16 2020a - Content Mapping Resource​

Page 1339​

Code Value​

Code Meaning​

Definition​

Notes​

128126​ Plane through Leftmost Extent​A plane passing through the leftmost extent of the​ referenced feature​

128127​ PlanethroughRightmostExtent​A plane passing through the rightmost extent of the​ referenced feature​

128128​ Plane through Anterior Extent​ A plane passing through the anterior extent of the​ referenced feature​

128129​ Plane through Posterior Extent​A plane passing through the posterior extent of the​

 

 

referenced feature​

128130​

Plane through Center​

A plane passing approximately through the center of the​

 

 

referenced feature​

128137​

Geometric Centerpoint​

The geometric center point of a feature, such as an​

 

 

organ, implanted device or morphologic anomaly.​

128138​

Center of Mass​

The center of mass of a feature, such as an organ,​

 

 

implanted device or morphologic anomaly​

128144​

Impaired Renal Function​

The procedure is contraindicated for patients with​

 

 

impaired renal function.​

128151​

Laser Cross-hairs​

Positioning the patient based on alignment of laser​

 

 

cross-hairs.​

128160​

Acquired Volume​

Theanatomicalregionrepresentedintheacquireddata.​

128170​

Abdominal Radiology​

Organizational department or section responsible for​

 

 

Abdominal Radiology​

128171​

Biomedical Engineering​

Organizational department or section responsible for​

 

 

Biomedical Engineering​

128172​

Cardiovascular Radiology​

Organizational department or section responsible for​

 

 

Cardiovascular Radiology​

128173​

Information Technology​

Organizational department or section responsible for​

 

 

Information Technology​

128174​

Medical Physics​

Organizational department or section responsible for​

 

 

Medical Physics​

128175​

Musculoskeletal Radiology​

Organizational department or section responsible for​

 

 

Musculoskeletal Radiology​

128177​

Pediatric Radiology​

Organizational department or section responsible for​

 

 

Pediatric Radiology​

128179​

Thoracic Radiology​

Organizational department or section responsible for​

 

 

Thoracic Radiology​

128180​

For RT Workflow​

Instancesavailableasinputforageneralradiotherapeutic​

 

 

workflow.​

128181​

Diagnostic Source Images​

Instances used to make a diagnosis.​

128182​

Segmentation Result​

Instances created during a segmentation session.​

128183​

Registration Result​

Instances created during a spatial registration.​

128184​

Pre-Planning Result​

Instances created during preparation prior to planning.​

128185​

RT Prescription Result​

Instances created for prescription of a radiotherapeutic​

 

 

treatment.​

128186​ Dose Calculation Image Series​Image instances that represent an image series that is​ intended to be the primary input for the dose calculation.​ Any parameters required for dose calculation (such as​ electron density) is derived from this series.​

- Standard -​


Page 1340​

DICOM PS3.16 2020a - Content Mapping Resource​

 

Code Value​

Code Meaning​

Definition​

Notes​

128187​ Coordinate Alignment Image​ Image instances that represent an image series from​ Series​ which the display coordinate system for a​

radiotherapeutictreatmentplanningisderived.Typically​ this series does not provide the parameters required for​ the dose calculation.​

128188​ RTTreatmentSimulationResult​Instances created during the simulation of a​

 

 

radiotherapeutic treatment delivery session. May also​

 

 

include input objects actually used.​

128189​

RT Planning Result​

Instances created during the planning of a​

 

 

radiotherapeutictreatment.Mayalsoincludeinputobjects​

 

 

actually used.​

128190​

Dosimetric Result​

Instances created during the creation of the dosimetric​

 

 

result of a radiotherapeutic treatment plan. May also​

 

 

include input objects actually used.​

128191​ PatientSetupVerificationResult​Instances created during the verification of the patient’s​ treatmentposition.Mayalsoincludeinputobjectsactually​ used.​

128192​ RT Treatment Session Result​ Instancescreatedduringthetreatmentsession.Mayalso​ include input objects actually used.​

128193​ RTTreatmentCourseSummary​Instances created during a treatment course. May also​

 

 

include input objects actually used.​

128194​ RT Treatment QA Result​

Instances created during evaluation of the treatment​

 

 

delivery quality. May also include input objects actually​

 

 

used.​

128195​

For Diagnosis​

Instances available to make a diagnosis.​

128196​

For Segmentation​

Instances available for segmentation.​

128197​

For RT Prescription​

Instances available for prescribing a radiotherapeutic​

 

 

treatment delivery.​

128198​ For RT Treatment Planning​

Instances available for creating a radiotherapeutic​

 

 

treatment plan.​

128199​

For Plan Comparison​

Instances available for comparing plans.​

128200​ For RT Plan Summation​

Instances available to combine radiotherapeutic plans​

 

 

or doses.​

128201​

For Physician Review​

Instances available for review by a physician.​

128202​

For Physicist Review​

Instances available for review by a physicist.​

128203​

For Tumor Board​

Instances available for review of a tumor board.​

128204​ For Plan Quality Assurance​

Instances available to perform quality assurance of a​

 

 

radiotherapeutic treatment delivery plan.​

128205​ For Machine Quality Assurance​Instances available to perform quality assurance of one​

 

 

of the hardware or software components involved in a​

 

 

radiotherapeutic treatment delivery.​

128206​

For Patient Setup Verification​ Instancesavailableforverificationofthepatienttreatment​

 

 

position.​

128207​

For Clinical Trial Submission​

Instancesavailableforsubmissionforaclinicaltrialstudy.​

128208​

For Tumor Registry​

Instances available for submission to a tumor registry.​

128209​

RT Workflow Input Used​

Instancesusedasaninputofageneralradiotherapeutic​

 

 

workflow.​

128210​

RT Prescription Input Used​

Instances used for prescribing a radiotherapeutic​

 

 

treatment delivery.​

- Standard -​



 

DICOM PS3.16 2020a - Content Mapping Resource​

Page 1341​

Code Value​

Code Meaning​

Definition​

Notes​

128211​ RT Treatment Planning Input​

Instances used to create a radiotherapeutic treatment​

 

 

Used​

plan.​

 

128212​ RT Plan Summation Input Used​Instances used to combine radiotherapeutic plans or​

 

 

 

doses.​

 

128213​

Physician Review Input Used​ Instances used for review by a physician.​

 

128214​ Physicist Review Input Used​

Instances used for review by a physicist.​

 

128215​ Plan Quality Assurance Input​

Instances used to perform quality assurance of a​

 

 

Used​

radiotherapeutic treatment delivery plan.​

 

128216​

Machine Quality Assurance​

Instances used to perform quality assurance of one of​

 

 

Input Used​

the hardware or software components involved in a​

 

 

 

radiotherapeutic treatment delivery.​

 

128217​ Patient Setup Verification Input​Instancesusedduringverificationofthepatienttreatment​

 

 

Used​

position.​

 

128218​

Diagnosis Input Used​

Instances used to make a diagnosis.​

 

128219​

Contouring Input Used​

Instances used for segmentation.​

 

128220​ Plan Comparison Input Used​

Instances used for comparing plans.​

 

128221​ Tumor Board Input Used​

Instances used for review of a tumor board.​

 

128222​ Tumor Registry Input Used​

Instances submitted to a tumor registry.​

 

128223​ Clinical Trial Submission Input​Instances submitted to a clinical trial study.​

 

 

Used​

 

 

128224​

Source measurement​

Measurement used as the source for derivation.​

 

128225​

Source report​

Report used as the source for derivation.​

 

128226​

Source raw data​

Raw Data used as the source for derivation.​

 

128227​ Source real world value map​

Real world value map used as the source for derivation.​

 

 

 

E.g.,themapappliedtosourceimagesbeforeprocessing​

 

 

 

them, such as for a threshold based segmentation​

 

 

 

operation.​

 

128230​

Pulse Sequence Name​

NameofanMRpulsesequenceforannotationpurposes.​

 

 

 

Potentially vendor-specific name.​

 

128250​ Structural image for image​

A structural image used for image processing.​

 

 

processing​

 

 

128251​ Flow image for image​

A flow image used for image processing.​

 

 

processing​

 

 

128252​ OCT-A amplitude decorrelation​OCT angiography method that de-correlates the​ amplitudes between two consecutive B-scans from the​ narrowed spectral bands was computed, and all the​ decorrelation values within certain repeated B-scans​ were averaged to visualize blood vessels. Methods and​ algorithms for optical coherence tomography-based​ angiography: a review and comparison. Anqi Zhang ;​ QinqinZhang;Chieh-LiChen;RuikangK.Wang(2015).​ See http://biomedicaloptics.spiedigitallibrary.org/​ article.aspx?articleid=2464650#QuantitativeComparisons.​

- Standard -​


Page 1342​

DICOM PS3.16 2020a - Content Mapping Resource​

 

Code Value​

Code Meaning​

Definition​

Notes​

128253​

OCT-A complex variance​

OCT angiography method based on variations in the​

 

 

 

complex (amplitude and phase) OCT signal from​

 

 

 

repeated B-scans at the same location. There are a​

 

 

 

number of factors that may cause a change in the OCT​

 

 

 

signalfrequencyrelativetothesignalduetostatictissue​

 

 

 

background. These factors include, for example, the​

 

 

 

Doppler effect that induces optical frequency shift and​

 

 

 

thechangeinbackscatteringduetotheparticlesthatare​

 

 

 

moving in and out of the OCT-probe volume during​

 

 

 

imaging. The changes in signal frequency cause the​

 

 

 

changesinboththeamplitudeandthephaseoftheOCT​

 

 

 

signal.Comparisonofthecomplex(amplitudeandphase)​

 

 

 

signal from repeated B-scans at the same location​

 

 

 

provides an image that has higher contrast in areas of​

 

 

 

erythrocyte motion. This method is referred to as​

 

 

 

OCT-based micro-angiography - complex (OMAGC).​

 

128254​

OCT-A speckle variance​

OCT angiography method that analyzes the temporal or​

 

 

 

spatial statistics of the intensity of speckle from OCT​

 

 

 

images and identifies blood vessels.​

 

128255​

OCT-A correlation mapping​

OCTangiographymethodthatdifferentiatesflowregions.​

 

 

 

Static regions usually have high correlation values while​

 

 

 

flow regions have lower correlation values.​

 

128256​

Doppler OCT-A​

OCTangiographymethodthatutilizestheDopplerphase​

 

 

 

resolved information to provide the velocity of flow.​

 

 

 

Sometimes referred to as the phase variance method.​

 

128257​

Retina depth encoded​

ImageusingpseudocolorstoillustratemultipleOPTENF​

 

 

vasculature flow​

images obtained at various depth levels within the retina​

 

 

 

from the OPT flow volume.​

 

128258​ Retinadepthencodedstructural​ImageusingpseudocolorstoillustratemultipleOPTENF​

 

 

reflectance map​

images obtained at various depth levels within the retina​

 

 

 

from the OPT structural volume.​

 

128259​

Retina vasculature flow​

Imagethatillustratesthevasculatureflowwithintheentire​

 

 

 

retina. Generated from the OPT flow volume with pixels​

 

 

 

approximately from inner limiting membrane (ILM) to​

 

 

 

photoreceptor inner segment/ellipsoid region (ISe).​

 

128260​

Retina structural reflectance​

ImagethatillustratestheOCTstructuralreflectancewithin​

 

 

map​

the entire retina. Generated from the OPT structural​

 

 

 

volume with pixels approximately from inner limiting​

 

 

 

membrane(ILM)tophotoreceptorinnersegment/ellipsoid​

 

 

 

region (ISe).​

 

128261​

Vitreous vasculature flow​

Image that illustrates the vasculature flow within the​

 

 

 

vitreous.GeneratedfromtheOPTflowvolumewithpixels​

 

 

 

approximately from a selected location anterior to ILM,​

 

 

 

to ILM. This space/potential space is referred clinically​

 

 

 

as the Vitreo-retinal Interface (VRI).​

 

128262​ Vitreous structural reflectance​ImagethatillustratestheOCTstructuralreflectancewithin​

 

 

map​

the vitreous. Generated from the OPT structural volume​

 

 

 

with pixels approximately from a selected location that​

 

 

 

is anterior to ILM, to ILM. This space/potential space is​

 

 

 

referred clinically as the Vitreo-retinal Interface (VRI).​

 

128263​ Radial peripapillary vasculature​Image that illustrates the OCT vasculature flow within​

 

 

flow​

theRNFLaroundtheopticdisk.GeneratedfromtheOPT​

 

 

 

flow volume with pixels approximately from ILM to the​

 

 

 

outer boundary of the RNFL.​

 

- Standard -​