DICOM PS3.16 2020a - Content Mapping Resource​

Page 1361​

Code Value​

Code Meaning​

Definition​

Notes​

129011​

Component Model​

A reference to a predecessor model that contributed to​

 

 

 

the creation of the current combined model.​

 

 

 

Thisincludessimpleassemblyofdiscretepiecesaswell​

 

 

 

asmorecomplexcombination.Forexample:byBoolean​

 

 

 

mathematical and similar operations.​

 

129012​

Educational Intent​

Intended for educational purposes.​

 

 

 

For example: patient or care-giver education/informed​

 

 

 

consent, or training residents and fellows.​

 

129013​

Planning Intent​

Intended to be used to assist with procedure planning​

 

129014​

Tool Fabrication​

Intended to be used to manufacture a patient-matched​

 

 

 

tool that is employed during a medical procedure.​

 

 

 

For example: drill/cutting guides, immobilizers, radiation​

 

 

 

shields, and plate bending templates.​

 

129015​

Prosthetic Fabrication​

Intended to be used to manufacture a fully external​

 

 

 

prosthetic/orthotic​

 

129016​

Implant Fabrication​

Intended to be used to manufacture a wholly or partially​

 

 

 

internal implant​

 

129017​

Simulation Intent​

Intended to be used for simulation and/or practice of a​

 

 

 

surgery or other medical procedure. "Simulation" is not​

 

 

 

used for patient-matched simulation, as this would be​

 

 

 

covered by "Diagnostic Intent" or "Planning Intent".​

 

129018​ US 3D CAM model​

A 3D manufacturing model derived from ultrasound​

 

 

 

imaging.​

 

129019​ Mixed Modality 3D CAM model​A 3D manufacturing model derived from images from​

 

 

 

multiple different modalities.​

 

129020​ Photogrammetric Imaging 3D​ A 3D manufacturing model derived from measurements​

 

 

CAM model​

made from photographs.​

 

129021​ Laser Scanning 3D CAM model​A 3D manufacturing model derived from laser scanning​

 

 

 

measurements.​

 

129100​

Fat fraction​

The fraction of fat present, derived using Dixon or other​

 

 

 

techniques.​

 

129101​

Water/fat in phase​

Water/Fat In Phase signal, derived using Dixon or other​

 

 

 

techniques.​

 

129102​ Water/fat out of phase​

Water/Fat Out of phase signal, derived using Dixon or​

 

 

 

other techniques.​

 

129103​

Water fraction​

The fraction of water present, derived using Dixon or​

 

 

 

other techniques.​

 

129104​

Perfusion image analysis​

Analysis of perfusion images.​

 

129105​

Diffusion image analysis​

Analysis of diffusion images.​

 

129106​

Diffusion tractography​

Estimation of the course of fiber tracts by analysis of​

 

 

 

anisotropic diffusion.​

 

129201​ Image used for Treatment​

Images that have been used in the treatment planning​

 

 

Planning​

process.​

 

129202​

ImageusedforDoseCalculation​Images that have been used for dose calculation in the​

 

 

 

treatment planning process.​

 

129203​

Image Acquired during​

Images that have been acquired during a treatment​

 

 

Treatment​

session.​

 

- Standard -​


Page 1362​

DICOM PS3.16 2020a - Content Mapping Resource​

 

Code Value​

Code Meaning​

Definition​

Notes​

129204​ ImageusedasReferenceImage​Imagesthatareusedinatreatmentsessionasreference​

 

 

for Treatment​

images to position the patient.​

 

129210​

Registration used in Planning​ Registrations that have been used in the treatment​

 

 

 

planning process​

 

129211​

Registration created during​

Registrations that have been created in the execution of​

 

 

Treatment​

a treatment session​

 

129301​

Coil Marker​

A coil-shaped marker visible in an image.​

 

129303​

Cylinder Marker​

A cylinder-shaped marker visible in an image.​

 

129305​

Wire Marker​

A thread or rod-shaped marker visible in an image.​

 

129306​

Transponder Marker​

A marker that receives a radio signal and transmits a​

 

 

 

response.​

 

129308​

MR Marker​

A marker containing a substance that produces a​

 

 

 

distinctive signal on MR images.​

 

129309​

Infrared Reflector Marker​

Infrared reflecting external marker, e.g., attached to skin​

 

 

 

or stereotactic frame.​

 

129310​

Visible Reflector Marker​

Visible light reflecting external marker, e.g., attached to​

 

 

 

skin or stereotactic frame.​

 

129320​

Effective Atomic Number​

The average atomic number for a compound or mixture​

 

 

 

ofmaterials.Thereareavarietyofmethodsforestimating​

 

 

 

this value for a given compound.​

 

129321​

Modified Hounsfield Unit​

Modified pixel values within the Hounsfield Unit Value​

 

 

 

range.​

 

129322​

Value-based Image​

Eachreal-worldvaluemappedpixelrepresentsacertain​

 

 

 

value for a specified material (the exact interpretation of​

 

 

 

the value range has to be defined by the user).​

 

129323​

Material Specific Image​

Each real-world value mapped pixel value represents a​

 

 

 

propertytheattenuationofamaterialsuchasattenuation,​

 

 

 

concentration or density.​

 

129324​

Material Removed Image​

Image with the attenuation contribution of one or more​

 

 

 

materials removed. For pixels that did not contain any of​

 

 

 

theremovedmaterial(s),thepixelvaluesareunchanged.​

 

129325​

Material Highlighted Image​

Imagewherepixelvalueshavebeenmodifiedtohighlight​

 

 

 

a certain target material by partially suppressing the​

 

 

 

background and/or by enhancing the modified material.​

 

129326​

Material Suppressed Image​

Imagewherepixelvalueshavebeenmodifiedtopartially​

 

 

 

suppress the modified material (opposite to Material​

 

 

 

Highlighted image).​

 

129327​

Material Recalculated Image​

Imagewherepixelsarerecalculatedbyavendor-specific​

 

 

 

method.​

 

129328​

Volume Occupancy Image​

Eachreal-worldvaluemappedpixelrepresentsafraction,​

 

 

 

by volume, occupied by the material.​

 

129329​

Mass Occupancy Image​

Eachreal-worldvaluemappedpixelrepresentsafraction,​

 

 

 

by mass, occupied by the material.​

 

130001​

Minimum Surface Radiation​

Anobjectivetoachievearadiationdosewhichisgreater​

 

 

Dose​

than or equal to the specified radiation dose at the​

 

 

 

surface of a volume.​

 

130002​

Maximum Surface Radiation​

An objective to achieve a radiation dose which is less​

 

 

Dose​

than or equal to the specified radiation dose at the​

 

 

 

surface of a volume.​

 

- Standard -​


 

DICOM PS3.16 2020a - Content Mapping Resource​

Page 1363​

Code Value​

Code Meaning​

Definition​

Notes​

130003​

Minimum Radiation Dose​

Anobjectivetoachievearadiationdosewhichisgreater​

 

 

 

than or equal to the specified radiation dose throughout​

 

 

 

a volume.​

 

130004​

Maximum Radiation Dose​

An objective to achieve a radiation dose which is less​

 

 

 

than or equal to the specified radiation dose throughout​

 

 

 

a volume.​

 

130005​ Minimum Mean Radiation Dose​An objective to achieve a mean radiation dose over the​ volume which is greater than or equal to the specified​ radiation dose.​

130006​ MaximumMeanRadiationDose​An objective to achieve a mean radiation dose over the​

 

 

volume which is less than or equal to the specified​

 

 

radiation dose.​

130007​

Minimum Equivalent Uniform​

Anobjectivetoachieveanequivalentuniformdose(EUD)​

 

Dose​

which is greater than or equal to the specified radiation​

 

 

dose.​

130008​ Maximum Equivalent Uniform​ Anobjectivetoachieveanequivalentuniformdose(EUD)​

 

Dose​

whichislessthanorequaltothespecifiedradiationdose.​

130009​

Prescription Radiation Dose​

An objective to achieve a radiation dose which is equal​

 

 

to the specified radiation dose throughout the volume.​

130010​

Minimum Conformity Index​

An objective to achieve a conformity index which is​

 

 

greater than or equal to the specified conformity index​

 

 

for a radiation dose which is equal to the specified​

 

 

radiation dose throughout the volume.​

 

 

MinimumConformityIndexasdefinedin[Feuvret],page​

 

 

335.​

130011​

Minimum Healthy Tissue​

Anobjectivetoachieveahealthytissueconformityindex​

 

Conformity Index​

which is greater than or equal to the specified healthy​

 

 

tissueconformityindexforaradiationdosewhichisequal​

 

 

to the specified radiation dose throughout the volume.​

 

 

Minimum Healthy Tissue Conformity Index as defined in​

 

 

[Feuvret], page 335.​

130012​ MinimumConformationNumber​An objective to achieve a conformation number which is​

 

 

greater than or equal to the specified conformation​

 

 

numbergreaterforaradiationdosewhichisequaltothe​

 

 

specified radiation dose throughout the volume.​

 

 

Minimum Conformation Number as defined in [Feuvret],​

 

 

page 335.​

130013​

Maximum Homogeneity Index​An objective to achieve a homogeneity index which is​

 

 

less than or equal to the specified homogenity index for​

 

 

a radiation dose which is equal to the specified radiation​

 

 

dose throughout the volume.​

 

 

Maximum Homogeneity Index as defined in [Feuvret],​

 

 

page 335.​

130014​ Minimum Percent Volume at​

Anobjectivetoachievearadiationdosewhichisgreater​

 

Radiation Dose​

than or equal to the specified radiation dose for at least​

 

 

a specified volume percentage.​

130015​ Maximum Percent Volume at​

An objective to achieve a radiation dose which is less​

 

Radiation Dose​

than or equal to the specified radiation dose for at least​

 

 

a specified "volume percentage.​

- Standard -​


Page 1364​

DICOM PS3.16 2020a - Content Mapping Resource​

 

Code Value​

Code Meaning​

Definition​

Notes​

130016​ Minimum Absolute Volume at​ Anobjectivetoachievearadiationdosewhichisgreater​ Radiation Dose​ than or equal to the specified radiation dose for at least​

a specified volume size.​

130017​ Maximum Absolute Volume at​An objective to achieve a radiation dose which is less​

 

Radiation Dose​

than or equal to the specified radiation dose for at least​

 

 

a specified volume size.​

130018​

Minimize Meterset​

An objective to minimize the total Meterset.​

130019​

Specified Radiation Dose​

The radiation dose value for a Dosimetric Objective.​

130020​

Specified Volume Size​

The specified volume size of an anatomical region in a​

 

 

Dosimetric Objective.​

130021​ Specified Volume Percentage​ Thepercentagewhichrepresentsafractionalparameter​

 

 

used by a Dosimetric Objective.​

130022​ Radiation Characteristics Note​Freetextnotedescribingcharacteristicsoftheradiation.​

130023​

Beam Shaping Note​

Free text note describing the devices and techniques​

 

 

used to shape the radiation beam.​

130024​

Treatment Planning Note​

Free text note to describe suggestions or advice to​

 

 

treatment planning.​

130025​

Special Procedure Note​

Freetextnotedescribingadditionalactivitiesthataddress​

 

 

individual patient needs.​

130026​

Patient Positioning Note​

Free text note describing the process to position the​

 

 

patient for the procedure.​

130027​

4D Radiation Treatment Note​ Free text note describing management of patient motion​

 

 

during the radiation treatment.​

130028​

Patient Setup Note​

Free text note describing the setup of the patient on the​

 

 

patient support device(s).​

130029​

Previous Treatment Note​

Freetextnotedescribingpreviouslydeliveredtreatments.​

130030​

Planning Imaging Note​

Free text note describing the intended use of images for​

 

 

planning.​

130031​

Delivery Verification Note​

Free text note describing how delivery is to be verified.​

130032​

Simulation Note​

Free text note describing preferred simulation​

 

 

procedures.​

130033​

Radiation Therapy Particle​

Particle used for Radiotherapy treatment.​

130034​

RT Beam Energy​

Energy of the Radiotherapy treatment beam.​

130035​ Patient Positioning Procedure​ Free text note describing the procedure "for acquiring​

 

Note​

and applying information about patient position.​

130036​

QA Process Note​

FreetextnotedescribingtheQualityAssuranceProcess​

 

 

for the treatment of the patient.​

130037​

Ion Therapy Particle​

Particle for a radiotherapeutic treatment using beams of​

 

 

energetic protons, positive ions or other particles.​

130038​

Brachytherapy Isotope​

Isotopeforaradiotherapeutictreatmentwhereadecaying​

 

 

radiation source is placed inside or next to a target area,​

 

 

called Brachytherapy.​

130039​

Adaptive Radiation Therapy​

Free text note describing how adaptive radiotherapy is​

 

Note​

to be performed.​

130040​

Teletherapy Isotope​

Isotopeforaradiotherapeutictreatmentwhereadecaying​

 

 

radiation source is placed outside the body.​

- Standard -​


 

DICOM PS3.16 2020a - Content Mapping Resource​

Page 1365​

Code Value​

Code Meaning​

Definition​

Notes​

130041​

RT Target​

Volume containing tissues to be irradiated to a specified​

 

 

 

radiation dose, typically encompassing a tumor, and​

 

 

 

possibly including surrounding subclinical disease, and​

 

margin(s) to account for uncertainties in patient​ positioning and organ motion.​

130042​ RT Dose Calculation Structure​Non-target structure or volume used when calculating​

 

the radiation dose, e.g. during an optimzation process.​

 

This may be a structure whose proximity to the target​

 

and/or radiosensitivity restrict the radiation dose​

 

deliverable to the target.​

130043​ RT Geometric Information​

Points or volumes used as spatial references, e.g.,​

 

treatmentorimagingdeviceisocenterorfiducialmarkers.​

130044​ Fixation or Positioning Device​ Device used to reproducibly position or limit the motion​

 

 

of a patient or portion of a patient during treatment.​

130045​

Brachytherapy Device​

Device used to deliver Brachtherapy treatments. This​

 

 

includes both devices containing radioactive sources​

 

 

(seeds, eye plaques) and devices used to position​

 

 

radioactive sources (source applicators, channels etc.).​

130046​

Non-specific Volume​

A volume that does not represent a named physical​

 

 

entity.​

130047​

External Body Structure​

A volume representing the external shape of the patient​

 

 

body used in radiotherapeutic procedures.​

130048​

Unclassified Volume​

A volume that does not correspond to an identifiable​

 

 

physical entity and has user specified boundaries.​

130049​

CTV Nodal​

Clinical Target Volume encompassing diseased lymph​

 

 

node(s) , with margin to include surrounding sub-clinical​

 

 

disease as defined in [ICRU Report 50].​

130050​

CTV Primary​

Clinical Target Volume encompassing primary tumor(s)​

 

 

, with margin to include surrounding sub-clinical disease​

 

 

as defined in [ICRU Report 50].​

130051​

GTV Nodal​

Gross Tumor Volume encompassing diseased lymph​

 

 

nodes as defined in [ICRU Report 50].​

130052​

GTV Primary​

Gross Tumor Volume encompassing primary tumor(s)​

 

 

as defined in [ICRU Report 50].​

130053​

PTV Nodal​

Planning Target Volume encompassing a nodal CTV,​

 

 

with margin to account for uncertainty in patient​

 

 

positioningandorganmotionasdefinedin[ICRUReport​

 

 

50].​

130054​

PTV Primary​

Planning Target Volume encompassing a primary CTV,​

 

 

with margin to account for uncertainty in patient​

 

 

positioningandorganmotionasdefinedin[ICRUReport​

 

 

50].​

130055​ Entire Body Target Volume​

Entire Body as a target volume for radiotherapy​

 

 

treatment. The usual term for a treatment technique​

 

 

irradiating this target is Full Body Irradiation.​

130056​

ITV​

Internal Target Volume encompassing the CTV, with​

 

 

margin to account for internal motion, often delineated​

 

 

using multiple images, e.g., acquired over a breathing​

 

 

cycle,cardiaccycle,etc,asdefinedin[ICRUReport50].​

- Standard -​