DICOM PS3.16 2020a - Content Mapping Resource​ Page 173​

Table TID 3111. Percutaneous Entry​

 

NL​ RelwithParent​ VT​

Concept Name​

VM​ Req Type​Condition​Value Set Constraint​

1​

 

CODE​

EV (121156, DCM,​

1​

M​

DCID 3403​

 

 

 

"PercutaneousEntryAction")​

 

 

“Percutaneous Entry”​

2​

>​

HASCONCEPT​CODE​

EV (272741003, SCT,​

1​

U​

DCID 244 “Laterality”​

 

 

MOD​

"Laterality")​

 

 

 

3​

>​

INCLUDE​

DTID 3010 “Log Entry​

1​

U​

 

 

 

 

Qualifiers”​

 

 

 

TID 3112 Specimen Obtained​

The Specimen Obtained Template allows recording of obtaining a specimen, and the identifiers for that specimen. This is particularly​ designedforbloodsamplesthatwillbeanalyzedforbloodoxygen-relatedmeasurements.Theanalysisofthesamplemayberecorded​ in one or more log entries using TID 3109 “Measurements”, or in a separate Structured Report SOP Instance referenced by a log​ entry using TID 3103 “Referenced Object”.​

Type:​

Extensible​

Order:​

Significant​

Root:​

No​

Table TID 3112. Specimen Obtained​

 

NL​ Rel with Parent​ VT​

Concept Name​

VM​

Req​

Condition​ Value Set Constraint​

 

 

 

 

 

 

Type​

 

 

1​

 

 

CODE​

EV (121123, DCM, "Patient​

1​

M​

 

DCID 3515 “Specimen​

 

 

 

 

Status or Event")​

 

 

 

Collection”​

2​

>​

HAS ACQ​

CODE​

EV (371439000, SCT,​

1​

UC​

IFF​

DCID 3520 “Blood​

 

 

CONTEXT​

 

"Specimen Type")​

 

 

specimen is​Source Type”​

 

 

 

 

 

 

 

bloodsample​

3​

>​

HAS ACQ​

CODE​

EV (363704007, SCT,​

1​

U​

 

BCID 3630​

 

 

CONTEXT​

 

"Procedure site")​

 

 

 

“Cardiovascular​

 

 

 

 

 

 

 

 

Anatomic Locations”​

4​

>​

HAS​

INCLUDE​ DTID 1009 “Subject​

1​

U​

 

 

 

 

PROPERTIES​

 

Context, Specimen”​

 

 

 

 

TID 3113 Patient Support​

The Patient Support Template allows recording of the use of various support technologies, including oxygen, ventilation, pacing, etc.​

Type:​

Extensible​

Order:​

Significant​

Root:​

No​

 

Table TID 3113. Patient Support​

NL​

Rel with​

VT​

Concept Name​

VM​

Req​ Condition​

Value Set​

 

Parent​

 

 

 

Type​

Constraint​

1​

 

CODE​

DCID 3530 “Oxygen​

1​

U​

DCID 3531 “Oxygen​

 

 

 

Administration Actions”​

 

 

Administration”​

2​ >​

HAS​

NUM​

EV (121160, DCM, "Oxygen​

1​

MC​ IFF Row 1​

UNITS = DT (l/min,​

 

PROPERTIES​

Administration Rate")​

 

Concept is​

UCUM, "l/min")​

 

 

 

 

 

(121161, DCM,​

 

 

 

 

 

"Begin Oxygen​

 

 

 

 

 

Administration")​

- Standard -​


Page 174​

DICOM PS3.16 2020a - Content Mapping Resource​

 

 

NL​ Rel with​

VT​

Concept Name​

VM​

Req​ Condition​

Value Set​

 

Parent​

 

 

 

Type​

Constraint​

3​

>​

INCLUDE​

DTID 3010 “Log Entry​

1​

U​

 

 

 

 

Qualifiers”​

 

 

 

4​

 

CODE​

DCID 3550 “Circulatory​

1​

U​

DCID 3553​

 

 

 

Support Actions”​

 

 

“CirculatorySupport”​

5​

>​

INCLUDE​

DTID 3010 “Log Entry​

1​

U​

 

 

 

 

Qualifiers”​

 

 

 

6​

 

CODE​

DCID 3551 “Ventilation​

1​

U​

DCID 3554​

 

 

 

Actions”​

 

 

“Ventilation”​

7​

>​

INCLUDE​

DTID 3010 “Log Entry​

1​

U​

 

 

 

 

Qualifiers”​

 

 

 

8​

 

CODE​

DCID 3552 “Pacing Actions”​

1​

U​

DCID 3555 “Pacing”​

9​

>​

INCLUDE​

DTID 3010 “Log Entry​

1​

U​

 

 

 

 

Qualifiers”​

 

 

 

TID 3114 Patient Assessment​

ThePatientAssessmentTemplateallowsrecordingoftheassessmentofthepatient'scardiovascular,neurological,and/orrespiratory​ condition. A particular use of this Template is for "vital signs", which are a specific subset of mandatory patient assessment measure-​ ments.​

Type:​

Extensible​

Order:​

Significant​

Root:​

No​

 

Table TID 3114. Patient Assessment​

 

NL​ Rel with​

VT​

Concept Name​

VM​ Req​

Condition​

Value Set Constraint​

 

 

Parent​

 

 

Type​

 

1​

 

 

CODE​

EV (121123, DCM,​

1​ M​

 

DT (121165, DCM, "Patient​

 

 

 

 

"Patient Status or​

 

 

Assessment Performed")​

 

 

 

 

Event")​

 

 

DT (61746007, SCT,​

 

 

 

 

 

 

 

 

 

 

 

 

 

 

"Observation of Vital Signs")​

2​

>​

HAS​

INCLUDE​DTID 300​

1​ MC​IF Row 1 value =​

$Measurement = EV​

 

 

PROPERTIES​

“Measurement”​

 

(61746007, SCT,​

(271649006, SCT, "Systolic​

 

 

 

 

 

 

"Observation of Vital​blood pressure")​

 

 

 

 

 

 

Signs")​

$Units = DCID 3500 “Pressure​

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Units”​

 

 

 

 

 

 

 

$Method = BCID 3560 “Blood​

 

 

 

 

 

 

 

Pressure Methods”​

3​

>​

HAS​

INCLUDE​DTID 300​

1​ MC​IF Row 1 value =​

$Measurement = EV​

 

 

PROPERTIES​

“Measurement”​

 

(61746007, SCT,​

(271650006, SCT, "Diastolic​

 

 

 

 

 

 

"Observation of Vital​blood pressure")​

 

 

 

 

 

 

Signs")​

$Units = DCID 3500 “Pressure​

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Units”​

4​

>​

HAS​

INCLUDE​DTID 300​

1​ MC​IF Row 1 value =​

$Measurement = EV (8867-4,​

 

 

PROPERTIES​

“Measurement”​

 

(61746007, SCT,​

LN, "Heart rate")​

 

 

 

 

 

 

"Observation of Vital​

 

 

 

 

 

 

Signs")​

$Units=EV({H.B.}/min,UCUM,​

 

 

 

 

 

 

 

"BPM")​

- Standard -​


 

 

 

 

DICOM PS3.16 2020a - Content Mapping Resource​

Page 175​

 

NL​ Rel with​

VT​

Concept Name​

VM​ Req​

Condition​

Value Set Constraint​

 

 

Parent​

 

 

 

Type​

 

5​

>​

HAS​

INCLUDE​DTID 300​

1​ MC​IF Row 1 value =​

$Measurement = EV (8310-5,​

 

 

PROPERTIES​

“Measurement”​

 

 

(61746007, SCT,​

LN, "Body temperature")​

 

 

 

 

 

 

 

"Observation of Vital​

 

 

 

 

 

 

 

Signs")​

$Units = EV (Cel, UCUM, "C")​

6​

>​

HAS​

INCLUDE​DTID 300​

1​ MC​IF Row 1 value =​

$Measurement = DCID 3526​

 

 

PROPERTIES​

“Measurement”​

 

 

(61746007, SCT,​

“Blood Gas Saturation”​

 

 

 

 

 

 

 

"Observation of Vital​

 

 

 

 

 

 

 

Signs")​

$Units = EV (%, UCUM, "%")​

7​

>​

HAS​

INCLUDE​DTID 300​

1​ MC​IF Row 1 value =​

$Measurement=EV(86290005,​

 

 

PROPERTIES​

“Measurement”​

 

 

(61746007, SCT,​

SCT, "Respiration rate")​

 

 

 

 

 

 

 

"Observation of Vital​

 

 

 

 

 

 

 

Signs")​

$Units = EV (/min, UCUM,​

 

 

 

 

 

 

 

 

"breaths/min")​

8​

>​

HAS​

INCLUDE​DTID 300​

1-n​ MC​IF Row 1 value =​

$Measurement = EV (122195,​

 

 

PROPERTIES​

“Measurement”​

 

 

(61746007, SCT,​

DCM, "Pulse Strength")​

 

 

 

 

 

 

 

"Observation of Vital​

 

 

 

 

 

 

 

Signs")​

$Method = BCID 3442​

 

 

 

 

 

 

 

 

“Peripheral Pulse Methods”​

 

 

 

 

 

 

 

 

$TargetSite = BCID 3440​

 

 

 

 

 

 

 

 

“Peripheral Pulse Locations”​

 

 

 

 

 

 

 

 

$Units = DT ({0:4}, UCUM,​

 

 

 

 

 

 

 

 

"range 0:4")​

9​

>​

HAS​

INCLUDE​DTID 300​

1​ MC​IF Row 1 value =​

$Measurement = EV​

 

 

PROPERTIES​

“Measurement”​

 

 

(61746007, SCT,​

(225908003,SCT,"PainScore")​

 

 

 

 

 

 

 

"Observation of Vital​

 

 

 

 

 

 

 

Signs")​

$Units = DT ({1:10}, UCUM,​

 

 

 

 

 

 

 

 

"range 1:10")​

10​

>​

HAS​

CODE​

DT (8884-9, LN,​

1​

U​

 

BCID 3415 “Cardiac Rhythms”​

 

 

PROPERTIES​

"Cardiac Rhythm")​

 

 

 

 

11​

>​

HAS​

CODE​

DT (9304-7, LN,​

1​

U​

 

BCID 3416 “Respiration​

 

 

PROPERTIES​

"Respiration​

 

 

 

Rhythms”​

 

 

 

 

Rhythm")​

 

 

 

 

12​

>​

HAS​

CODE​

DT (364062005,​

1​

U​

 

BCID3448“AirwayAssessment”​

 

 

PROPERTIES​

SCT, "Respiration​

 

 

 

 

 

 

 

 

Assessment")​

 

 

 

 

13​

>​

HAS​

CODE​

DT (364528001,​

1-n​

U​

 

BCID 3446 “Skin Condition”​

 

 

PROPERTIES​

SCT, "Skin​

 

 

 

 

 

 

 

 

condition")​

 

 

 

 

14​ >​

HAS​

CODE​

DT (363871006,​

1​

U​

 

 

 

 

PROPERTIES​

SCT, "Patient mental​

 

 

 

 

 

 

 

state assessment")​

 

 

 

 

15​

>​

HAS​

TEXT​

BCID 3441 “Patient​ 1-n​

U​

 

 

 

 

PROPERTIES​

Assessments”​

 

 

 

 

Content Item Descriptions​

 

 

 

 

 

Row 8​

Pulse Strength allows the assessment of the patient's pulse at multiple locations using the Topographical​

 

 

concept modifier. It may also be used for a single pulse strength measurement from an unspecified location,​

 

 

as is typical of vital signs assessments.​

 

 

 

Row 16​

Allows free text description of patient assessments that are not expressible by coded entries of Rows 10 to​

 

 

14.​

 

 

 

 

 

 

- Standard -​


Page 176​

DICOM PS3.16 2020a - Content Mapping Resource​

TID 3115 ECG ST Assessment​

The ECG ST Assessment Template allows recording of the assessment of changes in the patient ECG relative to baseline.​

Type:​

Extensible​

Order:​

Significant​

Root:​

No​

Table TID 3115. ECG ST Assessment​

 

NL​ Rel with Parent​ VT​

Concept Name​

VM​

Req​

Condition​Value Set Constraint​

 

 

 

 

 

 

Type​

 

1​

 

 

CODE​

EV (121123, DCM, "Patient​

1​

M​

DT (258181008, SCT,​

 

 

 

 

Status or Event")​

 

 

"ECG Analysis")​

2​

>​

HAS​

NUM​

DT (122099, DCM, "ST​

1-n​

M​

UNITS = EV (uV, UCUM,​

 

 

PROPERTIES​

 

change from baseline")​

 

 

"uV")​

3​

>>​

HAS CONCEPT​CODE​

DT (122148, DCM, "Lead​

1​

M​

BCID 3001 “ECG Leads”​

 

 

MOD​

 

ID")​

 

 

 

Quantitative Ventricular Analysis Report SR IOD Templates ​

The Templates that comprise the Quantitative Ventricular Analysis SR are interconnected as in Figure A-3:​

TID 3202

 

 

TID 1002

Ventricular

 

 

Observer

Analysis

 

 

Context

 

 

 

TID 1204

 

 

 

Language of

 

 

 

Content Item and

 

 

 

Descendants

 

 

 

TID 3602

 

 

 

Patient

 

 

 

Characteristics

 

 

 

TID 3205

 

 

 

Calibration

 

 

 

TID 3520

 

 

 

Hemodynamic

 

 

 

Clinical Context

 

 

 

TID 3206

 

 

 

AA Main Results

 

 

 

TID 3208

 

 

 

Frame to Frame

 

 

 

Results

 

 

 

TID 3209

 

 

 

Centerline Wall

 

 

 

Motion

 

 

 

TID 32011

 

 

 

Landmark Based

 

 

 

Wall Motion

Figure A-3. Quantitative Ventricular Analysis Report SR IOD Template Structure​

TID 3202 Ventricular Analysis​

The Ventricular Analysis Template provides a CONTAINER with a structure for reporting the result of the ventricular analysis.​

Type:​

Extensible​

Order:​

Significant​

Root:​

No​

- Standard -​


DICOM PS3.16 2020a - Content Mapping Resource​ Page 177​

Table TID 3202. Ventricular Analysis​

 

NL​

Rel with Parent​ VT​

Concept Name​

VM​

Req​

Condition​

Value Set​

 

 

 

 

 

 

Type​

 

Constraint​

1​

 

 

CONTAINER​EV (122292, DCM,​

1​

M​

 

 

 

 

 

 

"Quantitative​

 

 

 

 

 

 

 

 

Ventriculography Report")​

 

 

 

 

2​

>​

HAS CONCEPT​INCLUDE​

DTID 1204 “Language of​

1​

M​

 

 

 

 

MOD​

 

Content Item and​

 

 

 

 

 

 

 

 

Descendants”​

 

 

 

 

3​

>​

HAS OBS​

INCLUDE​

DTID 1002 “Observer​

1-n​

M​

 

 

 

 

CONTEXT​

 

Context”​

 

 

 

 

4​

>​

CONTAINS​

INCLUDE​

DTID 3602 “Cardiovascular​

1​

U​

 

 

 

 

 

 

Patient Characteristics”​

 

 

 

 

5​

>​

CONTAINS​

CONTAINER​EV (122144, DCM,​

1-n​

M​

 

 

 

 

 

 

"Quantitative Analysis")​

 

 

 

 

6​

>>​

HAS OBS​

INCLUDE​

DTID 1002 “Observer​

1-n​

U​

 

 

 

 

CONTEXT​

 

Context”​

 

 

 

 

7​

>>​

HAS OBS​

TEXT​

EV (111001, DCM,​

1​

M​

 

 

 

 

CONTEXT​

 

"Algorithm Name")​

 

 

 

 

8​

>>​

HAS OBS​

TEXT​

EV (111003, DCM,​

1​

M​

 

 

 

 

CONTEXT​

 

"Algorithm Version")​

 

 

 

 

9​

>>​

HAS OBS​

TEXT​

EV (122405, DCM,​

1​

M​

 

 

 

 

CONTEXT​

 

"Algorithm Manufacturer")​

 

 

 

 

10​

>>​

CONTAINS​

IMAGE​

EV (121112, DCM, "Source​ 1-n​

M​

 

 

 

 

 

 

of Measurement")​

 

 

 

 

11​

>>>​

HAS CONCEPT​CODE​

EV (246092007, SCT,​

1​

M​

 

DCID 12233​

 

 

MOD​

 

"Cardiac Phase")​

 

 

 

“Cardiac Phase”​

12​

>>>​

HAS CONCEPT​CODE​

EV (111031, DCM, "Image​

1​

MC​ If Biplane​

DCID3466“Plane​

 

 

MOD​

 

View")​

 

 

Analysis​

Identification”​

13​

>>​

HAS ACQ​

INCLUDE​

DTID 3205 “Calibration”​

1-2​

U​

VM = 1: Single​$CalibrationPlane​

 

 

CONTEXT​

 

 

 

 

plane analysis,​= DCID 3466​

 

 

 

 

 

 

 

VM=2:Biplane​“Plane​

 

 

 

 

 

 

 

analysis​

Identification”​

14​

>>​

HAS ACQ​

INCLUDE​

DTID 3520 “Hemodynamic​

1​

U​

 

 

 

 

CONTEXT​

 

Clinical Context”​

 

 

 

 

15​

>>​

CONTAINS​

INCLUDE​

DTID 3206 “VA Main​

1​

M​

 

 

 

 

 

 

Results”​

 

 

 

 

16​

>>​

CONTAINS​

INCLUDE​

DTID 3207 “AA Main​

1​

U​

 

 

 

 

 

 

Results”​

 

 

 

 

17​

>>​

CONTAINS​

INCLUDE​

DTID3208“Frame-to-Frame​

1​

U​

 

 

 

 

 

 

Results”​

 

 

 

 

18​

>>​

CONTAINS​

INCLUDE​

DTID 3209 “Centerline Wall​ 1-2​

U​

VM = 1: Single​

 

 

 

 

Motion”​

 

 

plane analysis,​

 

 

 

 

 

 

 

VM=2:Biplane​

 

 

 

 

 

 

 

analysis​

 

19​

>>​

CONTAINS​

INCLUDE​

DTID 3210 “Radial Based​

1-2​

U​

VM = 1: Single​

 

 

 

 

Wall Motion”​

 

 

plane analysis,​

 

 

 

 

 

 

 

VM=2:Biplane​

 

 

 

 

 

 

 

analysis​

 

- Standard -​