DICOM PS3.16 2020a - Content Mapping Resource​

Page 369​

 

NL​

Rel with Parent​

VT​

Concept Name​

VM​

Req​ Condition​ Value Set Constraint​

 

 

 

 

 

 

Type​

 

6​

>​

HAS CONCEPT​ CODE​

DT (125102, DCM, "Graft​

1​

U​

 

 

 

MOD​

 

Type")​

 

 

 

7​

>​

CONTAINS​

INCLUDE​

DTID 300 “Measurement”​ 1-n​

M​

$Measurement = DCID​

 

 

 

 

 

 

 

12119 “Vascular​

 

 

 

 

 

 

 

Ultrasound Property”​

Content Item Descriptions​

 

 

 

 

 

Proximal anastomosis​

 

The proximal location of the graft​

 

Distal anastomosis​

 

The distal location of the graft​

 

 

Graft type​

 

 

The type of graft, e.g., "in situ", "prosthetic", "autogenous"​

Echocardiography Procedure Report Templates ​

TID 5200 Echocardiography Procedure Report​

This Template forms the top of a content tree that allows an ultrasound device to describe the results of an adult echocardiography​ imaging procedure. It is instantiated at the root node. It can also be included in other Templates that need to incorporate echocardio-​ graphy findings into another report as quoted evidence.​

Type:​

Extensible​

Order:​

Significant​

Root:​

Yes​

Table TID 5200. Echocardiography Procedure Report​

 

NL​

Rel with​

VT​

Concept Name​

VM​ Req​Condition​

Value Set Constraint​

 

 

Parent​

 

 

 

Type​

 

 

1​

 

 

CONTAINER​EV (125200, DCM,​

1​

M​

Root node​

 

 

 

 

"Adult​

 

 

 

 

 

 

 

 

Echocardiography​

 

 

 

 

 

 

 

 

Procedure Report")​

 

 

 

 

2​

>​

HAS​

INCLUDE​

DTID 1204 “Language​ 1​

U​

 

 

 

 

CONCEPT​

 

of Content Item and​

 

 

 

 

 

 

MOD​

 

Descendants”​

 

 

 

 

3​

>​

HAS OBS​

INCLUDE​

DTID 1001​

1​

M​

 

 

 

 

CONTEXT​

 

“Observation Context”​

 

 

 

 

4​

>​

CONTAINS​ CONTAINER​DT (55111-9, LN,​

1​

U​

 

 

 

 

 

 

"Current Procedure​

 

 

 

 

 

 

 

 

Descriptions")​

 

 

 

 

5​

>>​

CONTAINS​ CODE​

DT (125203, DCM,​

1-n​

M​

BCID 12001 “Ultrasound Protocol​

 

 

 

 

"Acquisition Protocol")​

 

 

Types”​

6​

>​

CONTAINS​ INCLUDE​

DTID 5201​

1​

U​

 

 

 

 

 

 

“Echocardiography​

 

 

 

 

 

 

 

 

PatientCharacteristics”​

 

 

 

 

7​

>​

CONTAINS​ CONTAINER​EV (111028, DCM,​

1​

U​

 

 

 

 

 

 

"Image Library")​

 

 

 

 

8​

>>​

CONTAINS​ IMAGE​

 

1-n​

M​

 

 

- Standard -​


Page 370​

 

DICOM PS3.16 2020a - Content Mapping Resource​

 

 

 

NL​

Rel with​

VT​

Concept Name​

VM​ Req​Condition​

Value Set Constraint​

 

 

Parent​

 

 

 

Type​

 

 

9​

>​

CONTAINS​ INCLUDE​

DTID 5202 “Echo​

1​

U​

$SectionSubject = EV (87878005,​

 

 

 

 

Section”​

 

 

SCT, "Left Ventricle")​

 

 

 

 

 

 

 

$MeasType = DCID 12200​

 

 

 

 

 

 

 

“Echocardiography Left Ventricle”​

10​

>​

CONTAINS​ INCLUDE​

DTID 5202 “Echo​

1​

U​

$SectionSubject = EV (53085002,​

 

 

 

 

Section”​

 

 

SCT, "Right Ventricle")​

 

 

 

 

 

 

 

$MeasType = DCID 12204​

 

 

 

 

 

 

 

“Echocardiography Right Ventricle”​

11​

>​

CONTAINS​ INCLUDE​

DTID 5202 “Echo​

1​

U​

$SectionSubject = EV (82471001,​

 

 

 

 

Section”​

 

 

SCT, "Left Atrium")​

 

 

 

 

 

 

 

$MeasType = DCID 12205​

 

 

 

 

 

 

 

“Echocardiography Left Atrium”​

12​

>​

CONTAINS​ INCLUDE​

DTID 5202 “Echo​

1​

U​

$SectionSubject = EV (73829009,​

 

 

 

 

Section”​

 

 

SCT, "Right Atrium")​

 

 

 

 

 

 

 

$MeasType = DCID 12206​

 

 

 

 

 

 

 

“Echocardiography Right Atrium”​

13​

>​

CONTAINS​ INCLUDE​

DTID 5202 “Echo​

1​

U​

$SectionSubject = EV (34202007,​

 

 

 

 

Section”​

 

 

SCT, "Aortic Valve")​

 

 

 

 

 

 

 

$MeasType = DCID 12211​

 

 

 

 

 

 

 

“Echocardiography Aortic Valve”​

14​

>​

CONTAINS​ INCLUDE​

DTID 5202 “Echo​

1​

U​

$SectionSubject = EV (91134007,​

 

 

 

 

Section”​

 

 

SCT, "Mitral Valve")​

 

 

 

 

 

 

 

$MeasType = DCID 12207​

 

 

 

 

 

 

 

“Echocardiography Mitral Valve”​

15​

>​

CONTAINS​ INCLUDE​

DTID 5202 “Echo​

1​

U​

$SectionSubject = EV (39057004,​

 

 

 

 

Section”​

 

 

SCT, "Pulmonic Valve")​

 

 

 

 

 

 

 

$MeasType = DCID 12209​

 

 

 

 

 

 

 

“Echocardiography Pulmonic Valve”​

16​

>​

CONTAINS​ INCLUDE​

DTID 5202 “Echo​

1​

U​

$SectionSubject = EV (46030003,​

 

 

 

 

Section”​

 

 

SCT, "Tricuspid Valve")​

 

 

 

 

 

 

 

$MeasType = DCID 12208​

 

 

 

 

 

 

 

“Echocardiography Tricuspid Valve”​

17​

>​

CONTAINS​ INCLUDE​

DTID 5202 “Echo​

1​

U​

$SectionSubject = EV (15825003,​

 

 

 

 

Section”​

 

 

SCT, "Aorta")​

 

 

 

 

 

 

 

$MeasType = DCID 12212​

 

 

 

 

 

 

 

“Echocardiography Aorta”​

18​

>​

CONTAINS​ INCLUDE​

DTID 5202 “Echo​

1​

U​

$SectionSubject = EV (81040000,​

 

 

 

 

Section”​

 

 

SCT, "Pulmonary artery")​

 

 

 

 

 

 

 

$MeasType = DCID 12210​

 

 

 

 

 

 

 

“EchocardiographyPulmonaryArtery”​

19​

>​

CONTAINS​ INCLUDE​

DTID 5202 “Echo​

1​

U​

$SectionSubject = EV (35532006,​

 

 

 

 

Section”​

 

 

SCT, "Vena Cava")​

$MeasType = DCID 12215​

“Echocardiography Vena Cavae”​

- Standard -​



 

 

 

DICOM PS3.16 2020a - Content Mapping Resource​

 

Page 371​

 

NL​

Rel with​

VT​

Concept Name​

VM​ Req​Condition​

Value Set Constraint​

 

 

Parent​

 

 

 

Type​

 

 

20​

>​

CONTAINS​ INCLUDE​

DTID 5202 “Echo​

1​

U​

$SectionSubject = EV (122972007,​

 

 

 

 

Section”​

 

 

SCT,"PulmonaryVenousStructure")​

 

 

 

 

 

 

 

$MeasType = DCID 12214​

 

 

 

 

 

 

 

“EchocardiographyPulmonaryVeins”​

21​

>​

CONTAINS​ INCLUDE​

DTID 5202 “Echo​

1​

U​

$SectionSubject = EV (25489000,​

 

 

 

 

Section”​

 

 

SCT, "Pericardial cavity")​

 

 

 

 

 

 

 

$MeasType = DCID 12250 “Cardiac​

 

 

 

 

 

 

 

Ultrasound Common Linear​

 

 

 

 

 

 

 

Measurements”​

22​

>​

CONTAINS​ INCLUDE​

DTID 5202 “Echo​

1​

U​

$SectionSubject = EV (241213007,​

 

 

 

 

Section”​

 

 

SCT, "Cardiac Shunt Study")​

 

 

 

 

 

 

 

$MeasType = DCID 12217​

 

 

 

 

 

 

 

“Echocardiography Cardiac Shunt”​

23​

>​

CONTAINS​ INCLUDE​

DTID 5202 “Echo​

1​

U​

$SectionSubject = EV (9904008,​

 

 

 

 

Section”​

 

 

SCT, "Congenital Anomaly of​

 

 

 

 

 

 

 

Cardiovascular System")​

 

 

 

 

 

 

 

$MeasType = DCID 12218​

 

 

 

 

 

 

 

“Echocardiography Congenital”​

24​

>​

CONTAINS​ INCLUDE​

DTID 5204 “Wall​

1-n​

U​

$Procedure = DT (35757004, SCT,​

 

 

 

 

Motion Analysis”​

 

 

"Echocardiography for Determining​

 

 

 

 

 

 

 

Ventricular Contraction")​

Content Item Descriptions​

 

 

 

 

 

 

Row 8​

 

No purpose of reference is specified.​

 

 

 

Row 24​

 

The wall motion findings of stress stage. There may be multiple Template instances to report wall​

 

 

 

motion findings of multiple stages.​

 

 

 

 

TID 5201 Echocardiography Patient Characteristics​

Patient Characteristic concepts in this Template, which may replicate attributes in the Patient Study Module, are included here as​ possible targets of by-reference relationships from other Content Items in the SR tree.​

Note​

Several of the concepts in this Template duplicate concepts in TID 1007 “Subject Context, Patient”. The difference in use is​ that this Template has those concepts as primary observations of the patient, while in TID 1007 “Subject Context, Patient”​ the concepts are used to set (or reset) the context for other observations.​

Type:​

Extensible​

Order:​

Significant​

Root:​

No​

 

Table TID 5201. Echocardiography Patient Characteristics​

 

NL​ Rel with Parent​ VT​

Concept Name​

VM​

Req​ Condition​

Value Set​

 

 

 

 

Type​

Constraint​

1​

CONTAINER​EV (121118, DCM, "Patient​

1​

M​

 

 

 

Characteristics")​

 

 

 

- Standard -​


Page 372​

 

DICOM PS3.16 2020a - Content Mapping Resource​

 

 

NL​ Rel with Parent​ VT​

Concept Name​

VM​

Req​ Condition​ Value Set​

 

 

 

 

 

 

Type​

Constraint​

2​

>​

CONTAINS​

NUM​

EV (121033, DCM, "Subject​

1​

U​

UNITS = DCID​

 

 

 

 

Age")​

 

 

7456 “Units of​

 

 

 

 

 

 

 

Measure for Age”​

3​

>​

CONTAINS​

CODE​

EV (121032, DCM, "Subject​

1​

U​

DCID 7455 “Sex”​

 

 

 

 

Sex")​

 

 

 

4​

>​

CONTAINS​

NUM​

EV (8867-4, LN, "Heart Rate")​

1​

U​

 

5​

>​

CONTAINS​

NUM​

EV (271649006, SCT, "Systolic​

1​

U​

 

 

 

 

 

Blood Pressure")​

 

 

 

6​

>​

CONTAINS​

NUM​

EV(271650006,SCT,"Diastolic​

1​

U​

 

 

 

 

 

Blood Pressure")​

 

 

 

7​

>​

CONTAINS​

NUM​

EV (8277-6, LN, "Body Surface​

1​

M​

 

 

 

 

 

Area")​

 

 

 

8​

>>​

INFERRED​

CODE​

EV (8278-4, LN, "Body Surface​

1​

U​

BCID 3663 “Body​

 

 

FROM​

 

Area Formula")​

 

 

Surface Area​

 

 

 

 

 

 

 

Equations”​

TID 5202 Echo Section​

This is a generic section heading Template for any of the anatomical headings. Measurements within a section heading appear as​ groups (by image mode, acquisition protocol, and/or protocol stage).​

 

 

 

 

Table TID 5202. Parameters​

 

 

 

 

Parameter Name​

 

Parameter Usage​

 

$SectionSubject​

 

The subject modifier of the section heading container​

$MeasType​

 

 

The concept name of the measurement​

 

Type:​

Extensible​

 

 

 

Order:​

Significant​

 

 

 

Root:​

No​

 

 

 

 

 

 

 

 

Table TID 5202. Echo Section​

 

 

 

NL​

Rel with Parent​

VT​

Concept Name​

VM​

Req​ Condition​Value Set Constraint​

 

 

 

 

 

 

Type​

 

1​

 

 

CONTAINER​EV (121070, DCM,​

1​

M​

 

 

 

 

 

"Findings")​

 

 

 

2​

>​

HAS CONCEPT​ CODE​

EV (363698007, SCT,​

1​

M​

$SectionSubject​

 

 

MOD​

 

"Finding Site")​

 

 

 

3​

>​

CONTAINS​

CONTAINER​DT (125007, DCM,​

1-n​

M​

 

 

 

 

 

"Measurement Group")​

 

 

 

4​

>>​

HAS CONCEPT​ CODE​

EV (399264008, SCT,​

1​

U​

BCID 12224​

 

 

MOD​

 

"Image Mode")​

 

 

“Ultrasound Image​

 

 

 

 

 

 

 

Modes”​

5​

>>​

HAS CONCEPT​ CODE​

DT (125203, DCM,​

1​

U​

 

 

 

MOD​

 

"Acquisition Protocol")​

 

 

 

6​

>>​

HAS CONCEPT​ TEXT​

DT (125203, DCM,​

1​

U​

 

 

 

MOD​

 

"Acquisition Protocol")​

 

 

 

7​

>>​

HAS ACQ​

CODE​

EV (18139-6, LN, "Stage")​

1​

U​

BCID 12002​

 

 

CONTEXT​

 

 

 

 

“Ultrasound Protocol​

 

 

 

 

 

 

 

Stage Types”​