Page 1002 DICOM PS3.16 2020a - Content Mapping Resource
Table CID 8122. Microscopy Illuminator and Sensor Color
Coding Scheme |
Code Value |
Code Meaning |
SNOMED-RT ID |
UMLS Concept Unique ID |
Designator |
|
|
|
|
SCT |
414298005 |
Full Spectrum |
R-102C0 |
C1532530 |
SCT |
414497003 |
Infrared |
R-102BE |
C1532326 |
SCT |
371240000 |
Red |
G-A11A |
C1260956 |
SCT |
371246006 |
Green |
G-A11E |
C0332583 |
SCT |
405738005 |
Blue |
G-A12F |
C1260957 |
SCT |
415770004 |
Ultraviolet |
R-102BF |
C1532472 |
CID 8123 Microscopy Illumination Method
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Extensible |
Version: |
20100824 |
UID: |
1.2.840.10008.6.1.900 |
Table CID 8123. Microscopy Illumination Method
Coding Scheme Designator |
Code Value |
Code Meaning |
DCM |
111741 |
Transmission illumination |
DCM |
111742 |
Reflection illumination |
DCM |
111743 |
Epifluorescence illumination |
DCM |
111744 |
Brightfield illumination |
DCM |
111745 |
Darkfield illumination |
DCM |
111746 |
Oblique illumination |
DCM |
111747 |
Phase contrast illumination |
DCM |
111748 |
Differential interference contrast |
DCM |
111749 |
Total internal reflection fluorescence |
CID 8124 Microscopy Filter
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Extensible |
Version: |
20100824 |
UID: |
1.2.840.10008.6.1.901 |
Table CID 8124. Microscopy Filter
Coding Scheme |
Code Value |
Code Meaning |
SNOMED-RT ID UMLS Concept Unique |
Designator |
|
|
ID |
SCT |
445465004 |
Green optical filter |
SCT |
445279009 |
Red optical filter |
SCT |
445084008 |
Blue optical filter |
SCT |
445169002 |
Infrared optical filter |
SCT |
445391002 |
Polarizing optical filter |
SCT |
445278001 |
Violet optical filter |
SCT |
445254006 |
Ultraviolet optical filter |
SCT |
445316008 |
Dichroic beamsplitter |
A-010E2 |
C2919396 |
A-010DF |
C2919397 |
A-010DA |
C2919751 |
A-010DC |
C2919637 |
A-010E1 |
C2919554 |
A-010DE |
C2919567 |
A-010DD |
C2919555 |
A-0010F |
C2919671 |
|
DICOM PS3.16 2020a - Content Mapping Resource |
Page 1003 |
Coding Scheme |
Code Value |
Code Meaning |
SNOMED-RT ID |
UMLS Concept Unique |
Designator |
|
|
|
ID |
SCT |
445635004 |
Hoffman modulator |
SCT |
445624009 |
Darkfield stop |
SCT |
445623003 |
Rheinberg filter |
SCT |
445625005 |
Phase contrast plate |
SCT |
445634000 |
Condenser annulus |
SCT |
445633006 |
Nomarski prism |
SCT |
445663002 |
de Sénarmont compensator |
DCM |
111609 |
No filter |
A-00121 |
C2919672 |
A-0011D |
C2919815 |
A-0011C |
C2919816 |
A-0011E |
C2919530 |
A-00120 |
C2919531 |
A-0011F |
C2919532 |
A-00123 |
C2919789 |
CID 8125 Microscopy Illuminator Type
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Extensible |
Version: |
20100824 |
UID: |
1.2.840.10008.6.1.902 |
Table CID 8125. Microscopy Illuminator Type
Coding Scheme |
Code Value |
Code Meaning |
SNOMED-RT ID |
UMLS Concept Unique ID |
Designator |
|
|
|
|
SCT |
445679001 |
Tungsten halogen lamp |
A-00125 |
C2919726 |
SCT |
445685008 |
Mercury arc lamp |
A-00127 |
C2919809 |
SCT |
445671003 |
Xenon arc lamp |
A-00124 |
C2919810 |
SCT |
445683001 |
Light emitting diode |
A-00126 |
C2919811 |
SCT |
122456005 |
Laser |
A-23000 |
C0023089 |
CID 8130 Staining Protocols
This Context Group is intended for use in the Scheduled Protocol Code Sequence (0040,0008) and the Performed Protocol Code Sequence (0040,0260) attributes for an automated slide stainer. When so used, an Item with value (127790008, SCT, "Staining") will also include a Protocol Context Sequence (0040,0440) using TID 8003 “Specimen Staining” to identify the specific stain substance.
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Extensible |
Version: |
20111028 |
UID: |
1.2.840.10008.6.1.944 |
Table CID 8130. Staining Protocols
Coding Scheme |
Code Value |
Code Meaning |
SNOMED-RT ID |
UMLSConceptUniqueID |
Designator |
|
|
|
|
SCT |
127790008 |
Staining |
P3-00003 |
C0487602 |
SCT |
104210008 |
Hematoxylin and eosin stain |
P3-50495 |
C0523207 |
|
|
method |
|
|
CID 8131 Pathology Imaging Protocols
This Context Group is intended for use in the Scheduled Protocol Code Sequence (0040,0008) and the Performed Protocol Code Sequence(0040,0260).Whensoused,anItemwithvalue(112703,DCM,"WholeSlideImaging")mayalsoincludeaProtocolContext Sequence (0040,0440) using TID 8010 “Slide Imaging Parameters”.
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |