Page 1012 |
DICOM PS3.16 2020a - Content Mapping Resource |
CodingSchemeDesignator |
Code Value |
Code Meaning |
DCM |
121707 |
RT Patient Position Acquisition, CT kV |
DCM |
121708 |
RT Patient Position Acquisition, CT MV |
DCM |
121709 |
RT Patient Position Acquisition, Optical |
DCM |
121710 |
RT Patient Position Acquisition, Ultrasound |
DCM |
121711 |
RT Patient Position Acquisition, Spatial Fiducials |
CID 9243 Radiotherapy Registration Workitem Definition |
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Extensible |
|
Version: |
20110406 |
|
UID: |
1.2.840.10008.6.1.933 |
|
Table CID 9243. Radiotherapy Registration Workitem Definition |
CodingSchemeDesignator |
Code Value |
Code Meaning |
DCM |
121712 |
RT Patient Position Registration, single plane |
DCM |
121713 |
RT Patient Position Registration, dual plane |
DCM |
121714 |
RT Patient Position Registration, 3D CT general |
DCM |
121715 |
RT Patient Position Registration, 3D CT marker-based |
DCM |
121716 |
RT Patient Position Registration, 3D CT volume-based |
DCM |
121717 |
RT Patient Position Registration, 3D on 2D reference |
DCM |
121718 |
RT Patient Position Registration, 2D on 3D reference |
DCM |
121719 |
RT Patient Position Registration, Optical |
DCM |
121720 |
RT Patient Position Registration, Ultrasound |
DCM |
121721 |
RT Patient Position Registration, Spatial Fiducials |
CID 9250 Scheduled Processing Parameter Concept Codes for RT Treatment
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Extensible |
Version: |
20170413 |
UID: |
1.2.840.10008.6.1.971 |
Table CID 9250. Scheduled Processing Parameter Concept Codes for RT Treatment
Coding Scheme Designator |
Code Value |
Code Meaning |
DCM |
121740 |
Treatment Delivery Type |
CID 9300 Procedure Discontinuation Reasons
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Extensible |
Version: |
20181115 |
UID: |
1.2.840.10008.6.1.533 |
Table CID 9300. Procedure Discontinuation Reasons
Coding Scheme Designator |
Code Value |
Code Meaning |
DCM |
110526 |
Resource pre-empted |
DCM |
110527 |
Resource inadequate |
Page 1014 DICOM PS3.16 2020a - Content Mapping Resource
Table CID 9302. Media Import PPS Discontinuation Reasons
Coding Scheme Designator |
Code Value |
Code Meaning |
DCM |
110521 |
Objects incorrectly formatted |
DCM |
110522 |
Object Types not supported |
DCM |
110523 |
Object Set incomplete |
DCM |
110524 |
Media Failure |
DCM |
110501 |
Equipment failure |
DCM |
110510 |
Duplicate order |
DCM |
110513 |
Discontinued for unspecified reason |
DCM |
110514 |
Incorrect worklist entry selected |
CID 9303 Interpretation Request Discontinuation Reasons
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Extensible |
Version: |
20171122 |
UID: |
1.2.840.10008.6.1.1198 |
Table CID 9303. Interpretation Request Discontinuation Reasons
Coding Scheme |
Code Value |
Code Meaning |
Designator |
|
|
DCM |
110526 |
Resource pre-empted |
DCM |
110500 |
Doctor canceled procedure |
DCM |
110502 |
Incorrect procedure ordered |
DCM |
110504 |
Patient died |
DCM |
110509 |
Change of procedure for correct charging |
DCM |
110510 |
Duplicate order |
DCM |
110513 |
Discontinued for unspecified reason |
DCM |
110530 |
Workitem assignment rejected by assigned resource |
DCM |
110523 |
Object Set incomplete |
DCM |
110531 |
Insufficient quality for interpretation |
DCM |
110532 |
Interpretation requires specialist expertise |
CID 9401 IEC61217 Device Position Parameters
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Extensible |
Version: |
20130518 |
UID: |
1.2.840.10008.6.1.1023 |
|
Table CID 9401. IEC61217 Device Position Parameters |
Coding Scheme Designator Code Value Code Meaning
Include CID 9402 “IEC61217 Gantry Position Parameters” Include CID 9403 “IEC61217 Patient Support Position Parameters”
CID 9402 IEC61217 Gantry Position Parameters
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
|
DICOM PS3.16 2020a - Content Mapping Resource |
Page 1015 |
Type: |
Extensible |
|
Version: |
20130518 |
|
UID: |
1.2.840.10008.6.1.1024 |
|
Table CID 9402. IEC61217 Gantry Position Parameters
Coding Scheme Designator |
Code Value |
Code Meaning |
DCM |
126809 |
IEC61217 Gantry Continuous Roll Angle |
DCM |
126810 |
IEC61217 Gantry Continuous Pitch Angle |
DCM |
126811 |
IEC61217 Gantry Continuous Yaw Angle |
CID 9403 IEC61217 Patient Support Position Parameters
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Extensible |
Version: |
20130518 |
UID: |
1.2.840.10008.6.1.1025 |
Table CID 9403. IEC61217 Patient Support Position Parameters
Coding Scheme Designator |
Code Value |
Code Meaning |
DCM |
126801 |
IEC61217 Patient Support Continuous Yaw Angle |
DCM |
126802 |
IEC61217 Table Top Continuous Pitch Angle |
DCM |
126803 |
IEC61217 Table Top Continuous Roll Angle |
DCM |
126804 |
IEC61217 Table Top Eccentric Axis Distance |
DCM |
126805 |
IEC61217 Table Top Continuous Eccentric Angle |
DCM |
126806 |
IEC61217 Table Top Lateral Position |
DCM |
126807 |
IEC61217 Table Top Longitudinal Position |
DCM |
126808 |
IEC61217 Table Top Vertical Position |
CID 9500 Dosimetric Objective Types
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Extensible |
Version: |
20181112 |
UID: |
1.2.840.10008.6.1.1210 |
Table CID 9500. Dosimetric Objective Types
|
|
|
|
Coding Scheme Designator |
Code Value |
Code Meaning |
Include CID 9532 |
“No-Parameter Dosimetric Objectives” |
|
Include CID 9529 |
“Single Dose Dosimetric Objectives” |
|
Include CID 9530 |
“Percentage and Dose Dosimetric Objectives” |
|
Include CID 9531 |
“Volume and Dose Dosimetric Objectives” |
|
DCM |
130074 |
Specified Conformity Index |
DCM |
130075 |
Specified Healthy Tissue Conformity Index |
DCM |
130076 |
Specified Conformation Number |
DCM |
130077 |
Specified Homogeneity Index |
CID 9501 Prescription Anatomy Categories
Resources: HTML | FHIR JSON | FHIR XML | IHE SVS XML