DICOM PS3.16 2020a - Content Mapping Resource Page 1025
Table CID 9532. No-Parameter Dosimetric Objectives
Coding Scheme Designator |
Code Value |
Code Meaning |
DCM |
130018 |
Minimize Meterset |
CID 9533 Delivery Time Structure
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Extensible |
Version: |
20181112 |
UID: |
1.2.840.10008.6.1.1243 |
Table CID 9533. Delivery Time Structure
Coding Scheme Designator |
Code Value |
Code Meaning |
DCM |
130096 |
Single Fraction |
DCM |
130097 |
Standard Fractionation |
DCM |
130098 |
Hypo-fractionation |
DCM |
130099 |
Hyper-fractionation |
DCM |
130100 |
Continuous Temporary |
DCM |
130101 |
Continuous Permanent |
CID 9534 Radiotherapy Targets
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Extensible |
Version: |
20181112 |
UID: |
1.2.840.10008.6.1.1244 |
Table CID 9534. Radiotherapy Targets
Coding Scheme |
Code Value |
Code Meaning |
SNOMED-RT ID UMLS Concept |
Designator |
|
|
|
Unique ID |
DCM |
130049 |
CTV Nodal |
|
|
DCM |
130050 |
CTV Primary |
|
|
SCT |
228792002 |
CTV |
R-429EB |
C0454198 |
DCM |
130051 |
GTV Nodal |
|
|
DCM |
130052 |
GTV Primary |
|
|
SCT |
228791009 |
GTV |
R-429E0 |
C0475645 |
DCM |
130053 |
PTV Nodal |
|
|
DCM |
130054 |
PTV Primary |
|
|
SCT |
228793007 |
PTV |
R-429EC |
C0454199 |
DCM |
130056 |
ITV |
|
|
DCM |
130059 |
Treated Volume |
|
|
SCT |
228790005 |
Irradiated Volume |
R-429DF |
C0454197 |
DCM |
130055 |
Entire Body Target Volume |
|
|
DCM |
130063 |
RadiationDoseNormalizationPoint |
|
DCM |
130064 |
Radiation Dose Reference Point |
|
|
Page 1026 DICOM PS3.16 2020a - Content Mapping Resource
CID 9535 Radiotherapy Dose Calculation Roles
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Extensible |
Version: |
20181112 |
UID: |
1.2.840.10008.6.1.1245 |
Table CID 9535. Radiotherapy Dose Calculation Roles
Coding Scheme Designator |
Code Value |
Code Meaning |
DCM |
130057 |
Planning Organ At Risk Volume |
DCM |
130058 |
Avoidance Volume |
DCM |
130060 |
Organ At Risk |
DCM |
130061 |
Radiation Dose Shaping Volume |
DCM |
130062 |
Conformality Shell |
DCM |
130065 |
Dose Calculation Bounding Volume |
DCM |
130066 |
Radiation Interaction Volume |
CID 9536 Radiotherapy Prescribing and Segmenting Person Roles
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Extensible |
Version: |
20181112 |
UID: |
1.2.840.10008.6.1.1246 |
Table CID 9536. Radiotherapy Prescribing and Segmenting Person Roles
Coding Scheme |
Code Value |
Code Meaning |
SNOMED-RT ID UMLSConceptUniqueID |
Designator |
|
|
|
|
SCT |
158965000 |
Medical Practitioner |
J-0016E |
C1306754 |
SCT |
309343006 |
Physician |
J-004E8 |
C0031831 |
SCT |
159016003 |
Radiologic Technologist |
J-00187 |
C0402007 |
DCM |
128674 |
Lead Radiologic Technologist |
|
|
SCT |
3430008 |
Radiation Therapist |
J-06173 |
C0278604 |
SCT |
159016003 |
Radiographer |
J-00187 |
C0402007 |
SCT |
405277009 |
Resident |
J-005E6 |
C1320928 |
UMLS |
C1441532 |
Consulting Physician |
|
C1441532 |
UMLS |
C2985483 |
Radiation Physicist |
|
C2985483 |
UMLS |
C1708969 |
Medical Physicist |
|
C1708969 |
CID 9537 Effective Dose Calculation Method Categories
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Extensible |
Version: |
20181112 |
UID: |
1.2.840.10008.6.1.1247 |
Table CID 9537. Effective Dose Calculation Method Categories
Coding Scheme Designator |
Code Value |
Code Meaning |
DCM |
130126 |
Radiation transport-based methods |
DCM |
130127 |
Fractionation-based or temporally-based methods |
DICOM PS3.16 2020a - Content Mapping Resource Page 1027
CID 9538 Radiation Transport-based Effective Dose Method Modifiers
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Extensible |
Version: |
20181112 |
UID: |
1.2.840.10008.6.1.1248 |
Table CID 9538. Radiation Transport-Based Effective Dose Method Modifiers
Coding Scheme Designator |
Code Value |
Code Meaning |
DCM |
130128 |
Local Effect Model |
DCM |
130129 |
Microdosimetric Kinetic Model |
CID 9539 Fractionation-based Effective Dose Method Modifiers
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Extensible |
Version: |
20181112 |
UID: |
1.2.840.10008.6.1.1249 |
Table CID 9539. Fractionation-Based Effective Dose Method Modifers
Coding Scheme Designator |
Code Value |
Code Meaning |
DCM |
130130 |
Equivalent 2-Gray Fractions Model |
DCM |
130131 |
Linear-Quadratic Model |
DCM |
130132 |
Linear-Quadratic Model with Time Factor |
DCM |
130133 |
Linear-Quadratic-Linear Model |
DCM |
130134 |
Linear-Quadratic Model for Low-Dose Rate Brachytherapy |
CID 9541 Beam Limiting Device Types
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Non-Extensible |
Version: |
20190715 |
UID: |
1.2.840.10008.6.1.1288 |
Table CID 9541. Beam Limiting Device Types
Coding Scheme Designator |
Code Value |
Code Meaning |
DCM |
130330 |
Jaw Pair |
DCM |
130331 |
Leaf Pairs |
DCM |
130332 |
Variable Circular Collimator |
DCM |
130333 |
Single Leaves |
Include CID 9545 “Fixed Beam Limiting Device Types”
CID 9542 Compensator Device Types
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Extensible |
Version: |
20190715 |
UID: |
1.2.840.10008.6.1.1289 |
Page 1028 DICOM PS3.16 2020a - Content Mapping Resource
Table CID 9542. Compensator Device Types
Coding Scheme Designator |
Code Value |
Code Meaning |
DCM |
130340 |
Physical Compensator |
CID 9543 Radiotherapy Treatment Machine Modes
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Extensible |
Version: |
20190715 |
UID: |
1.2.840.10008.6.1.1290 |
Table CID 9543. Radiotherapy Treatment Machine Modes
Coding Scheme Designator |
Code Value |
Code Meaning |
DCM |
130341 |
Total Body Irradiation |
DCM |
130342 |
Total Skin Irradiation |
CID 9544 Radiotherapy Distance Reference Locations
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Non-Extensible |
Version: |
20190715 |
UID: |
1.2.840.10008.6.1.1291 |
Table CID 9544. Radiotherapy Distance Reference Locations
Coding Scheme Designator |
Code Value |
Code Meaning |
DCM |
130358 |
Nominal Radiation Source Location |
DCM |
130359 |
Treatment Machine Isocenter |
CID 9545 Fixed Beam Limiting Device Types
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Extensible |
Version: |
20190715 |
UID: |
1.2.840.10008.6.1.1292 |
Table CID 9545. Fixed Beam Limiting Device Types
Coding Scheme Designator |
Code Value |
Code Meaning |
Include CID 9517 “Radiotherapy Block Device Types” |
|
DCM |
130343 |
Electron Fixed Aperture |
DCM |
130344 |
Photon Fixed Aperture |
DCM |
130345 |
Intraoperative Fixed Aperture |
CID 9546 Radiotherapy Wedge Types
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Extensible |
Version: |
20190715 |
UID: |
1.2.840.10008.6.1.1293 |