Page 1034 DICOM PS3.16 2020a - Content Mapping Resource
CID 10006 X-Ray Filter Materials
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Extensible |
Version: |
20190817 |
UID: |
1.2.840.10008.6.1.539 |
Table CID 10006. X-Ray Filter Materials
Coding Scheme |
Code Value |
Code Meaning |
SNOMED-RT ID |
UMLS Concept Unique ID |
Designator |
|
|
|
|
SCT |
71128006 |
Molybdenum |
C-15000 |
C0026402 |
SCT |
12503006 |
Aluminum |
C-12000 |
C0002367 |
SCT |
66925006 |
Copper |
C-12700 |
C0009968 |
SCT |
59801003 |
Rhodium |
C-16700 |
C0035493 |
SCT |
767776000 |
Niobium |
|
C0028101 |
SCT |
767775001 |
Europium |
|
C0015180 |
SCT |
88488004 |
Lead |
C-13200 |
C0023175 |
SCT |
45215009 |
Tantalum |
C-15600 |
C0039297 |
SCT |
41967008 |
Silver |
C-13700 |
C0037125 |
SCT |
12597001 |
Tin |
C-13900 |
C0040238 |
CID 10007 X-Ray Filter Types
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Extensible |
Version: |
20131010 |
UID: |
1.2.840.10008.6.1.540 |
Table CID 10007. X-Ray Filter Types
Coding Scheme Designator |
Code Value |
Code Meaning |
DCM |
113650 |
Strip filter |
DCM |
113651 |
Wedge filter |
DCM |
113652 |
Butterfly filter |
DCM |
113653 |
Flat filter |
DCM |
111609 |
No Filter |
CID 10008 Dose Related Distance Measurements
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Extensible |
Version: |
20170914 |
UID: |
1.2.840.10008.6.1.541 |
Table CID 10008. Dose Related Distance Measurements
Coding Scheme Designator |
Code Value |
Code Meaning |
DCM |
113748 |
Distance Source to Isocenter |
DCM |
113737 |
Distance Source to Reference Point |
DCM |
113750 |
Distance Source to Detector |
DCM |
113751 |
Table Longitudinal Position |
Page 1036 DICOM PS3.16 2020a - Content Mapping Resource
Table CID 10011. Effective Dose Evaluation Method
Coding Scheme Designator |
Code Value |
Code Meaning |
DCM |
113800 |
DLP to E conversion via MC computation |
DCM |
113801 |
CTDIfreeair to E conversion via MC computation |
DCM |
113802 |
DLP to E conversion via measurement |
DCM |
113803 |
CTDIfreeair to E conversion via measurement |
CID 10013 CT Acquisition Type
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Extensible |
Version: |
20160314 |
UID: |
1.2.840.10008.6.1.545 |
Table CID 10013. CT Acquisition Type
Coding Scheme |
Code Value |
Code Meaning |
SNOMED-RT ID |
UMLS Concept |
Designator |
|
|
|
Unique ID |
DCM |
113804 |
Sequenced Acquisition |
|
|
SCT |
116152004 |
Spiral Acquisition |
P5-08001 |
C0860888 |
DCM |
113805 |
Constant Angle Acquisition |
|
|
DCM |
113806 |
Stationary Acquisition |
|
|
DCM |
113807 |
Free Acquisition |
|
|
SCT |
702569007 |
Cone Beam Acquisition |
R-FB8F1 |
C3839509 |
CID 10014 Contrast Imaging Technique
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Extensible |
Version: |
20071031 |
UID: |
1.2.840.10008.6.1.546 |
Table CID 10014. Contrast Imaging Technique
Coding Scheme |
Code Value |
Code Meaning |
SNOMED-RT ID |
UMLS Concept Unique |
Designator |
|
|
|
ID |
SCT |
27483000 |
Diagnostic radiography with |
P5-00100 |
C0542435 |
|
|
contrast media |
|
|
SCT |
399331006 |
CT without contrast |
P5-0808E |
C1275400 |
CID 10015 CT Dose Reference Authorities
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Extensible |
Version: |
20081027 |
UID: |
1.2.840.10008.6.1.547 |
Table CID 10015. CT Dose Reference Authorities
Coding Scheme Designator |
Code Value |
Code Meaning |
DCM |
113808 |
ICRP Pub 60 |
DCM |
113841 |
ICRP Pub 103 |
DICOM PS3.16 2020a - Content Mapping Resource Page 1037
CID 10016 Anode Target Material
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Extensible |
Version: |
20190817 |
UID: |
1.2.840.10008.6.1.548 |
Table CID 10016. Anode Target Material
Coding Scheme |
Code Value |
Code Meaning |
SNOMED-RT ID |
UMLS Concept Unique ID |
Designator |
|
|
|
|
SCT |
71128006 |
Molybdenum |
C-15000 |
C0026402 |
SCT |
59801003 |
Rhodium |
C-16700 |
C0035493 |
SCT |
26194003 |
Tungsten |
C-16400 |
C0041383 |
CID 10017 X-Ray Grid
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Extensible |
Version: |
20070827 |
UID: |
1.2.840.10008.6.1.549 |
Table CID 10017. X-Ray Grid
Coding Scheme Designator |
Code Value |
Code Meaning |
DCM |
111641 |
Fixed grid |
DCM |
111642 |
Focused grid |
DCM |
111643 |
Reciprocating grid |
DCM |
111644 |
Parallel grid |
DCM |
111645 |
Crossed grid |
DCM |
111646 |
No grid |
CID 10020 Source of Projection X-Ray Dose Information
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Extensible |
Version: |
20120406 |
UID: |
1.2.840.10008.6.1.1054 |
Table CID 10020. Source of Projection X-Ray Dose Information
Coding Scheme |
Code Value |
Code Meaning |
SNOMED-RTIDUMLS Concept |
Designator |
|
|
|
Unique ID |
DCM |
113856 |
Automated Data Collection |
|
|
DCM |
113857 |
Manual Entry |
|
|
DCM |
113858 |
MPPS Content |
|
|
SCT |
15869005 |
Dosimeter |
A-2C090 |
C0180488 |
DCM |
113866 |
Copied From Image Attributes |
|
|
DCM |
113867 |
Computed From Image Attributes |
|
|
DCM |
113868 |
DerivedFromHuman-ReadableReports |
|
DCM |
113940 |
System Calculated |
|
|
Page 1038 DICOM PS3.16 2020a - Content Mapping Resource
CID 10021 Source of CT Dose Information
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Extensible |
Version: |
20081028 |
UID: |
1.2.840.10008.6.1.1055 |
Table CID 10021. Source of CT Dose Information
Coding Scheme Designator |
Code Value |
Code Meaning |
DCM |
113856 |
Automated Data Collection |
DCM |
113857 |
Manual Entry |
DCM |
113866 |
Copied From Image Attributes |
DCM |
113867 |
Computed From Image Attributes |
DCM |
113868 |
Derived From Human-Readable Reports |
CID 10022 Label Types
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Extensible |
Version: |
20110816 |
UID: |
1.2.840.10008.6.1.935 |
Table CID 10022. Label Types
Coding Scheme Designator |
Code Value |
Code Meaning |
DCM |
113607 |
Series Number |
DCM |
113608 |
Acquisition Number |
DCM |
113609 |
Instance Number |
CID 10023 Size Specific Dose Estimation Method for CT
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Extensible |
Version: |
20160314 |
UID: |
1.2.840.10008.6.1.947 |
Table CID 10023. Size Specific Dose Estimation Method for CT
Coding Scheme Designator |
Code Value |
Code Meaning |
DCM |
113934 |
AAPM 204 Lateral Dimension |
DCM |
113935 |
AAPM 204 AP Dimension |
DCM |
113936 |
AAPM 204 Sum of Lateral and AP Dimension |
DCM |
113937 |
AAPM 204 Effective Diameter Estimated From Patient Age |
DCM |
113981 |
Water Equivalent Diameter Representative Value |
DCM |
113982 |
Water Equivalent Diameter Integrated Across Scan Range |
DCM |
113983 |
Water Equivalent Diameter From Raw Data |
DCM |
113984 |
Water Equivalent Diameter From Localizer |
CID 10024 Water Equivalent Diameter Method
Resources: |
HTML | FHIR JSON | FHIR XML | IHE SVS XML |
Type: |
Extensible |