Page 1264 |
DICOM PS3.16 2020a - Content Mapping Resource |
|
Code Value |
Code Meaning |
Definition |
Notes |
113922 |
Radioactive Substance |
Type, amount and route of radioactive substance |
Retired. Replaced by |
|
Administered |
administered. |
(440252007, SCT, |
|
|
|
"Administration of |
|
|
|
radiopharmaceutical"). |
113923 |
Radiation Exposure and |
ExposuretoionizingradiationandassociatedpreventiveRetired. Replaced by |
|
Protection Information |
measures used to reduce the exposure of parts of the(73569-6, LN, "Radiation |
|
|
body like lead apron or eye, thyroid gland or gonad |
Exposure and Protection |
|
|
protection. |
Information") |
113930 Size Specific Dose EstimationThe Size-Specific Dose Estimate is a patient dose |
|
|
|
estimate that takes into account the size of the patient, |
|
|
such as described in [AAPM Report 204] or [AAPM |
|
|
|
Report220]byusinglineardimensionsmeasuredonthe |
|
|
patient or patient images or estimated from patient age. |
113931 |
Measured Lateral Dimension |
The side-to-side (left to right) dimension of the body part |
|
|
being scanned (per [AAPM Report 204]). |
|
113932 |
Measured AP Dimension |
The thickness of the body part being scanned, in the |
|
|
|
antero-posterior dimension (per [AAPM Report 204]). |
|
113933 |
Derived Effective Diameter |
The diameter of the patient at a given location along the |
|
|
Z-axis of the patient, assuming that the patient has a |
|
|
|
circular cross-section (per [AAPM Report 204]). |
|
113934 AAPM 204 Lateral Dimension The Size Specific Dose Estimation is computed using |
|
|
|
Table 1B (32cm phantom) or Table 2B (16cm phantom) |
|
|
of [AAPM Report 204]. |
|
113935 AAPM 204 AP Dimension |
The Size Specific Dose Estimation is computed using |
|
|
|
Table 1C (32cm phantom) or Table 2C (16cm phantom) |
|
|
of [AAPM Report 204]. |
|
113936 AAPM 204 Sum of Lateral andThe Size Specific Dose Estimation is computed using |
|
|
AP Dimension |
Table 1A (32cm phantom) or Table 2A (16cm phantom) |
|
|
of [AAPM Report 204]. |
|
113937 AAPM 204 Effective DiameterThe Size Specific Dose Estimation is computed using |
|
|
Estimated From Patient Age |
Table 1D (32cm phantom) or Table 2D (16cm phantom) |
|
|
using an effective diameter estimated from the patient's |
|
|
age using Table 3 of [AAPM Report 204]. |
|
113940 |
System Calculated |
Values calculated from other existing parameters. |
|
113941 |
In Detector Plane |
A segmented region of the detector surface within the |
|
|
|
irradiated area (but might not be near the center of the |
|
|
detector). |
|
113942 |
X-Ray Reading Device |
AdevicethatcreatesdigitalimagesfromX-Raydetectors |
|
|
(Direct, Indirect or Storage). |
|
113943 |
X-Ray Source Data Available ParametersrelatedtotheX-Raysource(generator,tube, |
|
|
etc) are available to the recording application. |
|
113944 |
X-Ray Mechanical Data |
Parameters related to the X-Ray Mechanical System |
|
|
Available |
(Stand,Table)areavailabletotherecordingapplication. |
113945 X-Ray Detector Data AvailableParameters related to the X-Ray Detector are available |
|
|
to the recording application. |
|
113946 |
Projection Eponymous Name Describes the radiographic method of patient, tube and |
|
|
detectorpositioningtoachieveawelldescribedprojection |
|
|
or view. |
|
113947 |
Detector Type |
Type of Detector used to acquire data. E.g., Images. |
|
113948 |
Direct Detector |
Detector that directly transforms the input signal to pixel |
|
|
values. |
|