DICOM PS3.16 2020a - Content Mapping Resource​

Page 1375​

Code Value​

Code Meaning​

Definition​

Notes​

130232​

Imaging Agent Administration​ Information about two-dimensional graph data for a​

 

 

Graph​

syringe or pump.​

 

130233​

Imaging Agent Administration​ Information about events that occurred at an injector​

 

 

Injector Events​

during an Imaging Agent administration.​

 

130234​

Imaging Agent Administration​ Type of event that occurred at an injector during an​

 

 

Injector Event Type​

Imaging Agent administration.​

 

130235​

Injector Event Detection​

Date and time when an injector event was detected.​

 

 

DateTime​

 

 

130236​

Planned Imaging Agent​

Reference to a Planned Imaging Agent Administration​

 

 

Administration SOP Instance​

SOP instance.​

 

130237​

Imaging Agent Administration​ Information about the activity in an Imaging Agent​

 

 

Activity​

administration phase. In an Automated Injection system​

 

 

 

this describes the activity of one of the pump or syringe​

 

 

 

units used.​

 

130238​

Imaging Agent Component​

Information about a component of an Imaging Agent.​

 

130239​

Component Volume​

Volume of one agent component in a mixture of multiple​

 

 

 

components.​

 

130240​

Total Phase Volume​

Total volume administered by all syringes/pump actions​

 

 

Administered​

during a single phase.​

 

130241​ TotalStepVolumeAdministered​Total volume administered by all syringes/pump actions​

 

 

 

within all phases during a single Step.​

 

130242​ Total number of manually​

Total number of times that an injection was triggered​

 

 

triggered injections​

manually.​

 

130244​ Peak Flow Rate in Phase​

Peak flow rate value detected at a specific location​

 

 

Activity​

(syringe or pump) during a specific activity of an​

 

 

 

administration phase.​

 

130245​ PeakPressureinPhaseActivity​Peak pressure value detected at a location (syringe or​

 

 

 

pump) during a single administration phase activity.​

 

130246​

Imaging Agent Administration​ UniqueidentificationofasingleperformedImagingAgent​

 

 

Performed Step UID​

administration step actually delivered on a specific​

 

 

 

occasion​

 

130247​

Patency Test Injection​

An injection of an inactive agent to test for blockages or​

 

 

 

leakages in the delivery path, usually performed prior to​

 

 

 

an administration of an imaging or therapeutic agent.​

 

130248​ Transit Time Test Injection​

AninjectionofabolusofImagingAgenttodeterminethe​

 

 

 

appropriate delay time for a diagnostic administration.​

 

130249​

Diagnostic Administration​

Administration of an Imaging Agent for the purpose of​

 

 

 

enhancing contrast in an image.​

 

130250​

Administration Step Type​

Type of step in an Imaging Agent administration. For​

 

 

 

example, a test administration or a diagnostic​

 

 

 

administration.​

 

130251​

Flush Administration​

Injection of an inactive fluid to clear the administration​

 

 

 

path of an active agent.​

 

130252​

Negative exponential​

A curve that decays exponentially from a specified start​

 

 

 

value, at a specified decay rate.​

 

- Standard -​


Page 1376​

DICOM PS3.16 2020a - Content Mapping Resource​

 

Code Value​

Code Meaning​

Definition​

Notes​

130253​

Linear Curve​

Acurvethatchangeslinearlyfromaspecifiedstartvalue​

 

 

 

to a specified end value.​

 

 

 

Note​

 

 

 

Note: The start value and the end value may​

 

 

 

be the same, indicating a flat curve.​

 

130254​

Imaging Agent Identifier​

Identifies an Imaging Agent uniquely within a set of​

 

 

 

Imaging Agents. The Imaging Agent may be a single​

 

 

 

component or a mix of multiple components.​

 

130255​

Referenced Imaging Agent​

The identifier of an Imaging Agent being referenced.​

 

 

Identifier​

 

 

130257​

Consumable Catheter Type​

Type of catheter used for Imaging Agent administration.​

 

130259​

Contrast Reaction Prophylactic​Apharmaceuticalagentadministeredasapre-medication​

 

 

Agent​

to prevent contrast reactions.​

 

130261​

Imaging Agent Administration​ Unique identification of a single Imaging Agent​

 

 

Performed Phase UID​

administration performed phase.​

 

130262​

Referenced Imaging Agent​

TheuniqueidentifieroftheImagingAgentadministration​

 

 

Administration Phase UID​

performed phase being referenced​

 

130290​

Median​

Towards the mid-sagittal plane of the body.​

 

130300​

Skin of paraspinal area of the​ Structure of skin of paraspinal area of the neck.​

 

 

neck​

 

 

130301​

Skin of paraspinal area of the​ Structure of skin of paraspinal area of the superior back.​

 

 

superior back​

 

 

130302​ Skin of upper paraspinal region​Structure of skin of upper paraspinal region.​

 

130303​

Skin of mid paraspinal region​

Structure of skin of mid paraspinal region.​

 

130304​ Skin of lower paraspinal region​Structure of skin of lower paraspinal region.​

 

130305​

Skin of anterior helix of ear​

Structure of skin of anterior helix of ear.​

 

130306​

Skin of caruncle of eye​

Structure of skin of caruncle of eye.​

 

130307​

Skin of inferior helix of ear​

Structure of skin of inferior helix of ear.​

 

130308​ Skin of inferior posterior surface​Structureofskinofinferiorposteriorsurfaceofthepinna.​

 

 

of the pinna​

 

 

130309​ Skin of lateral part of dorsum of​Structure of skin of lateral part of dorsum of foot.​

 

 

foot​

 

 

130310​

Skin of lower antihelix of ear​

Structure of skin of lower antihelix of ear.​

 

130311​

Skin of lower eyelid margin​

Structure of skin of lower eyelid margin.​

 

130312​

Skin of infraalar groove​

Structure of skin of infraalar groove.​

 

130313​ Skin of medial part of dorsum of​Structure of skin of medial part of dorsum of foot.​

 

 

foot​

 

 

130314​

Skin of paranasal cheek​

Structure of skin of paranasal cheek.​

 

130315​

Skin of posterior helix of ear​

Structure of skin of posterior helix of ear.​

 

130316​

Skin of posterior lobule of the​ Structure of skin of posterior lobule of the ear.​

 

 

ear​

 

 

130317​

Skin of sole of forefoot​

Structure of skin of sole of forefoot.​

 

130318​ Skin of superior antihelix of ear​Structure of skin of superior antihelix of ear.​

130319​ Skin of superior posterior helix​Structure of skin of superior posterior helix of ear.​ of ear​

- Standard -​


 

DICOM PS3.16 2020a - Content Mapping Resource​

Page 1377​

Code Value​

Code Meaning​

Definition​

Notes​

130320​ Skin of superior posterior​

Structure of skin of superior posterior surface of the​

 

 

surface of the pinna​

pinna.​

 

130321​ Skin of upper antihelix of ear​

Structure of skin of upper antihelix of ear.​

 

130322​ Skin of upper eyelid margin​

Structure of skin of upper eyelid margin.​

 

130323​ Skin of mid back​

Structure of skin of mid back.​

 

130324​

Functional condition present​

A functional condition present during acquisition, such​

 

 

during acquisition​

as phonation, weight bearing, voiding of the bladder or​

 

 

 

hemodynamic physiological challenges.​

 

130330​

Jaw Pair​

RT beam limiting device jaw pair​

 

130331​

Leaf Pairs​

RT beam limiting device multi-element leaf pairs​

 

130332​

Variable Circular Collimator​

A circular, aperture size adjustable beam limiting device​

 

 

 

for an RT treatment device.​

 

130333​

Single Leaves​

RT beam limiting device multi-element unpaired leaves​

 

130334​

X Orientation​

Oriented in the X direction of a defined coordinate​

 

 

 

system.​

 

130335​

Y Orientation​

Oriented in the Y direction of a defined coordinate​

 

 

 

system.​

 

130340​

Physical Compensator​

PhysicalRTexternalbeamcompensatortocompensate​

 

 

 

for inhomogeneity.​

 

130341​

Total Body Irradiation​

RT Treatment irradiating the body of the Patient in part​

 

 

 

or in whole.​

 

130342​

Total Skin Irradiation​

RT Treatment irradiating the surface of the skin of the​

 

 

 

Patient in part or in whole.​

 

126812​

Isocentric Patient Support​

Patient SupportContinuous Pitch Angle at the isocenter​

 

 

Continuous Pitch Angle​

position about the x-axis of the Equipment Coordinate​

 

 

 

System.​

 

126813​

Isocentric Patient Support​

Patient Support Continuous Roll Angle at the isocenter​

 

 

Continuous Roll Angle​

position about the y-axis of the Equipment Coordinate​

 

 

 

System.​

 

126814​

Isocentric Patient Support​

Patient Support Continuous Yaw Angle at the isocenter​

 

 

Continuous Yaw Angle​

position about the z-axis of the Equipment Coordinate​

 

 

 

System.​

 

126815​

Isocentric Patient Support​

Patient Support Lateral Position along the x-axis of the​

 

 

Lateral Position​

Equipment Coordinate System.​

 

126816​

Isocentric Patient Support​

Patient Support Longitudinal Position along the y-axis of​

 

 

Longitudinal Position​

the Equipment Coordinate System.​

 

126817​

Isocentric Patient Support​

Patient Support Vertical Position along the z-axis of the​

 

 

Vertical Position​

Equipment Coordinate System.​

 

130343​

Electron Fixed Aperture​

A type of device (or cone) for electron treatments that​

 

 

 

attaches to the applicator carriage of an RT treatment​

 

 

 

deviceforthepurposeofholdinganapertureandabolus​

 

 

 

closetothepatient'sskin.Severalbeamapplicatorsmay​

 

 

 

be available to reduce the weight of apertures lifted by​

 

 

 

therapists,decreasetheaperture/bolus-to-skindistance,​

 

 

 

and reduce leakage radiation.​

 

130344​

Photon Fixed Aperture​

A type of device (or cone) for photon treatments that is​

 

 

 

attachedtotheradiationheadofanRTtreatmentdevice​

 

 

 

into which beam modifiers are installed.​

 

- Standard -​


Page 1378​

DICOM PS3.16 2020a - Content Mapping Resource​

 

Code Value​

Code Meaning​

Definition​

Notes​

130345​

Intraoperative Fixed Aperture​ A type of device which is used to delimit the radiation of​

 

 

 

an RT treatment device in case of an intraoperative​

 

 

 

radiotherapeutic treatment.​

 

130346​

Hard Wedge​

A physical device placed inside the radiation head used​

 

 

 

to modify the fluence distribution across the field.​

 

130347​

Motorized Wedge​

Aphysicaldevicemanuallyplacedbetweentheradiation​

 

 

 

head and the patient used to modify the fluence​

 

 

 

distribution across the field. It is motorized and can be​

 

 

 

inserted/extracted from the beam path.​

 

130348​

Dynamic Wedge​

An effective wedge generated by the movement of a jaw​

 

 

 

across the treatment field while delivering radiation.​

 

130349​

Graticule​

Mechanical grid to embed scaling information in a​

 

 

 

radiographic image​

 

130350​

Reticle​

Mechanicalcrosshairtoembedacrosshairrepresenting​

 

 

 

axes and scaling information in a radiographic image​

 

130351​

Image Detector​

An electronic radiographic imaging device​

 

130352​

Film Holder​

Mechanical device to hold imaging film​

 

130353​

Winston-Lutz Pointer​

A spherical mechanical indicator used for alignment​

 

130354​

Bowtie Filter​

A bowtie-shaped filter used in imaging​

 

130355​

Flattening Filter Beam​

Beam that uses a filter to produce a nearly uniform​

 

 

 

intensity profile.​

 

130356​

Non-Flattening Filter Beam​

Beam that does not use a filter to produce a nearly​

 

 

 

uniform intensity profile.​

 

130357​

Partial Flattening Filter Beam​

Beamthatusesafiltertoproduceanearlyuniformregion​

 

 

 

across part of the intensity profile.​

 

128678​

Physics Assistant​

A medical professional capable of developing a​

 

 

 

radiotherapy plan from a Physicians prescription and​

 

 

 

assisting in radiation machine calibration and other​

 

 

 

radiotherapy quality assurance work under supervision​

 

 

 

of a Medical Physicist.​

 

130358​

Nominal Radiation Source​

The point location defined as the nominal source of​

 

 

Location​

radiation.​

 

130359​

Treatment Machine Isocenter​ Thecenterpointofthetreatmentmachinethroughwhich​

 

 

 

all beam central axes pass under all gantry angles.​

 

130360​

Fixed Laser Setup Point​

A fixed point at which initial patient setup is performed​

 

 

 

based on lasers.​

 

130361​ RadiotherapyTreatmentDevice​A device delivering radiotherapy treatments.​

 

130362​

Head Node Set​

Set of Robotic Nodes that can be used for targets​

 

 

 

associated with the patient's head.​

 

130363​

Body Node Set​

Set of Robotic Nodes that can be used for targets within​

 

 

 

the patient's body, excluding the head.​

 

130364​

Trigeminal Node Set​

Set of Robotic Nodes that can be used for targets near​

 

 

 

the patient's trigeminal nerve.​

 

130365​

QA Node Pair​

Two Robotic Nodes for Quality Assurance, for example​

 

 

 

daily checks.​

 

130366​

QA Node​

Single Robotic Node for Quality Assurance.​

 

130370​

RTV Rendition​

DICOMobjectscommunicatedintime-synchronizedflows​

 

 

 

using DICOM-RTV, intended for a simultaneous​

 

 

 

presentation.​

 

- Standard -​


 

DICOM PS3.16 2020a - Content Mapping Resource​

Page 1379​

Code Value​

Code Meaning​

Definition​

Notes​

130371​ RTV Audio and Video Rendition​Audio and Video DICOM objects communicated in​

 

 

 

time-synchronized flows using DICOM-RTV, intended​

 

 

 

for a simultaneous presentation.​

 

130372​

RTV Stereo Video Rendition​

Two Video DICOM objects communicated in​

 

 

 

time-synchronized flows using DICOM-RTV, intended​

 

 

 

for a stereo video.​

 

130373​ RTV Audio and Stereo Video​

Audio and two Video DICOM objects communicated in​

 

Rendition​

time-synchronized flows using DICOM-RTV, intended​

 

 

 

for a stereo video.​

 

130400​ Geometric purpose of region​

The purpose of defining a region. E.g., to define a​

 

 

 

bounding box, center or outline.​

 

130401​

Visual explanation​

A visual explanation of how an algorithm produced its​

 

 

 

results. E.g., for a machine learning application, a class​

 

 

activation or saliency map.​

 

130402​

Class activation​

Values are derived using global average pooling in​

Zhou B, Khosla A, Lapedriza​

 

 

convolutional neural networks to produce a localization​A, Oliva A, Torralba A.​

 

 

map highlighting the important regions in the image for​Learning Deep Features for​

 

 

predicting a class. The class activation map (CAM)​

Discriminative Localization.​

 

 

indicates the discriminative image regions used by the​IEEE Conference on​

 

 

network to identify a class.​

Computer Vision and Pattern​

 

 

 

Recognition (CVPR). 2016. p​

 

 

 

2921–9. http://dx.doi.org/​

 

 

 

10.1109/CVPR.2016.319​

130403​

Gradient-weighted class​

Values are derived using the gradients of a target class​Selvaraju RR, Cogswell M,​

 

activation​

flowingintothefinalconvolutionallayerofaconvolutional​Das A, Vedantam R, Parikh​

 

 

neuralnetworktoproducealocalizationmaphighlighting​D,BatraD.Grad-CAM:Visual​

 

 

the important regions in the image for predicting a class.​Explanations from Deep​

 

 

Thegradient-weightedclassactivationmap(Grad-CAM)​NetworksviaGradient-based​

 

 

indicates the discriminative image regions used by the​Localization. 2016. http://​

 

 

network to identify a class.​

arxiv.org/abs/1610.02391​

130404​

Saliency​

Valuesarederivedusingasingleback-propagationpass​Simonyan K, Vedaldi A,​

 

 

through a network to produce a localization map​

Zisserman A. Deep Inside​

 

 

highlightingthespatialsupportofagivenclassinagiven​Convolutional Networks:​

 

 

image.​

Visualising Image​

 

 

 

Classification Models and​

 

 

 

Saliency Maps. 2013. http://​

 

 

 

arxiv.org/abs/1312.6034​

130405​ Patient-Attached Dose Control​An object which is attached to the patient to attenuate​

 

 

Object​

the therapeutic dose (such as a Bolus or a lead shield).​

130406​

Non-uterine leiomyosarcoma​

A leiomyosarcoma (sarcoma containing large spindle​

 

 

 

cells of smooth muscle) occuring at a site other than the​

 

 

uterus.​

 

130407​ Bone and soft tissue​

Body structures of bone and soft tissue.​

 

- Standard -​